A
R6 control only: press the key SELC of the already programmed transmitter repeatedly, until displayed by the
led the selected channel
B
Set the dip-switches no.1 into ON position of both transmitters
C
Press and hold for 15 seconds the key PROG of the transmitter 1 already programmed
D
Release the key PROG of transmitter 1
E
Within 5 seconds press and hold for 5 seconds the key PROG of the transmitter 2 to be programmed
F
Set the transmitter dip-switch no. 1 of transmitters 1 and 2 into OFF position
G
Wait 10 seconds
H
Pressing the keys UP or DOWN the actuator moves in opening/closing direction
5.2.DIP-SWITCH 3: DELETION OF ALL THE STORED TRANSMITTERS
To delete all the transmitters stored on the actuator it is necessary using a remote control previously stored and
proceed as follows:
A
Power only the actuator to be reset
B
R6-CONTROL only: press the key SELC on the transmitter repeatedly until displayed the channel stored (by the
leds)
C
Set the transmitter dip-switch no.3 into ON position
D
Press and hold for at least 10 seconds the key PROG of the transmitter
E
Leave the key PROG and set the remote dip-switch no.3 into OFF position