Chapter 3. MilTouch
Raise Fill Temp—hot water valve on to raise temperature of filling water
Cold = Cold Water Valve
3.1.5.
OFF—cold water valve off
ON—cold water valve on
Lower Fill Temp—cold water valve on to lower temperature of filling water
3 = Third Water Valve (Optional)
3.1.6.
This decision is available only if the machine is equipped with and configured for optional third
water valve.
OFF—third water valve off
ON—third water valve on
Raise Fill Temp—third water valve on to raise temperature of filling water
Lower Fill Temp—third water valve on to lower temperature of filling water
Level = Bath Level
3.1.7.
Level 1—lowest bath level
Levels 2 - 5—intermediate bath levels
Level 6—highest bath level
Steam (Optional)
3.1.8.
This decision is available only if the machine is equipped with and configured for steam.
No Steam—Do not allow steam in this step
After, Runs—Start steaming after level is achieved, subsequent steaming allowed; timer runs.
Stops—Start steaming after level is achieved, subsequent steaming not allowed; timer stops
until temperature is achieved.
After, Stops—Start steaming after level is achieved, subsequent steaming allowed; timer stops
until temperature is achieved.
Early, After, Runs—Start steaming before level is achieved, subsequent steaming allowed;
timer runs.
Early, Stops—Start steaming before level is achieved, subsequent steaming not allowed; timer
stops until temperature is achieved.
Early, After, Stops—Start steaming before level is achieved, subsequent steaming allowed;
timer stops until temperature is achieved.
C = Chemicals
3.1.9.
There may be more than one chemical decision per step because multiple chemicals may be
added to a single bath.
If the chemical numbers and names shown below do not correspond to how your machine is set
up, do not use the default formulas without first testing and modifying the chemical injection
values.
0—no chemical injection commanded
1—inject chemical 1, usually alkali for 36-inch or larger models; detergent for other models