2—inject chemical 2, usually detergent for 36-inch or larger models; bleach for other models
3—inject chemical 3, usually bleach for 36-inch or larger models; sour for other models
4—inject chemical 4, usually softener
5—inject chemical 5, usually starch; also used to signal that a ChemSave machine desires to
inject chemical
W = When to Inject Chemicals
3.1.10.
At what point in the step is this chemical to be injected?
With Fill—Begin injecting the chemical when the water valves open.
Level OK—Begin injecting the chemical when the commanded bath level is achieved.
Level + Temp—Begin injecting the chemical when the commanded bath level and temperature
are achieved.
Chemical Dose = Chemical Injection Duration
3.1.11.
How long should the chemical injection continue?
00 00 00—0 seconds; chemical injection not allowed
00 00 40—40 seconds; default value
00 01 59—119 seconds
Signal with Chemical Injection
3.1.12.
Should the machine operator be notified when this chemical injection is desired?
No—The chemical injection occurs automatically without operator notification or intervention.
Yes—The machine will signal the operator when this chemical injection is desired. The operator
must cancel the signal before the injection will occur.
Wash Speed
3.1.13.
Set the wash speed in RPMs.
44—44 revolutions per minute
Drain Type
3.1.14.
What type of drain action is desired for this step? This decision may also affect the fill action.
Standard—Standard drain speed; cylinder turns clockwise at drain/distribution speed.
Two-Way Wash—Two-way wash speed; cylinder reverses at wash speed for additional
mechanical action during draining.
Do Not Drain—Do not drain; bath liquor is retained, as for the injection of additional chemicals
or for baths longer than the control will allow in a single step.
Stop with Fill—Stop with fill. The cylinder does not turn while filling prior to this drain, but
turns at standard drain speed during draining.
Stop with Drain—Stop with drain. The cylinder does not turn during draining.
Stop with Fill and Drain—Stop with fill and drain. The cylinder is held stationary during both
fill and drain.
RinSave—RinSave
a fixed time. At the end of that time, the drain opens. After a fixed time at drain/distribution
®
The cylinder turns clockwise at approximately 1G with the drain closed for