C:
RECIRCULATING (NON-VENTED – DUCTLESS)
INSTALLATION OVERVIEW
C1: Attach the mounting plate to the wall
C2: Use top cabinet template for preparation of the top
cabinet.
C3: Adapting blower for recirculation.
C4: Mount the microwave oven.
C5: Change the Charcoal Filter
C1:
ATTACH MOUNTING PLATE TO THE WALL
Attach the mounting plate to the wall using the wing nuts and machine screws (3/16" x 3"). At least one wood screw must
be used to attach the mounting plate to a wall stud.
3) Insert the machine screws (3/16" x 3") into the mounting plate through the holes designed to go into drywall and
attached the toggle wings to ¾" onto each machine screw (3/16" x 3").
4) Place the mounting plate against the wall and insert the toggle wings into the holes in the wall to mount the plate.
CAUTION: BE CARFUL TO AVOID PINCHING FINGERS BETWEEN THE BACK OF THE MOUNTING PLATE AND
THE WALL.
Tighten all bolts. Pull the mounting plate away from the wall to help tighten the bolts.
C2:
USE TOP CABINET TEMPLATE FOR PREPARATION OF TOP CABINET
You need to drill holes for the top support screws, a hole
large enough for the power cord to fit through, and a cutout
large enough for the exhaust adaptor.
• Read the instructions on the TOP CABINET TEMPLATE
• Tape it underneath the bottom of the top cabinet.
• Drill the holes, following the instructions on the TOP
CABINET TEMPLATE.
CAUTION: Wear safety goggles when drilling holes in the
cabinet
Step – by – Step Installation Guide
Moun�ng
Plate
22
To use toggle bolts
Spacing for Toggles More
Than Wall Thickness
Wing nut
machine
screw
Bolt End
Wall