Menu 5 Various settings
Menu
Entry
Selection
item
50
Key switch function (J7)
0
no function (default setting)
1
Inhibit control panel
2
Inhibit external control elements
3
Inhibit control panel and external control ele-
ments
4
Activate control elements for 10 seconds
5
Activate control elements for 300 seconds
52
001-256 Entry of control address
53
Door control module and inflatable door sealing.
0
Off (default setting)
1, 2, 3 For control profiles see door control module
54
Extended control
0
Off (default setting)
1, 2, 3 For control profiles see extended control
59
8
Do not change control variant!
- -
Exit menu
Menu 9 Service menu
menu
Entry
Selection
item
90
Selection of the door maintenance cycle
0
No service interval (default setting)
1
1000 cycles
2
4000 cycles
3
8000 cycles
4
12000 cycles
5
16000 cycles
6
20000 cycles
7
25000 cycles
8
30000 cycles
9
35000 cycles
10
40000 cycles
11
45000 cycles
12
50000 cycles
91
Cycle counter output door cycles
92
Selection of the loading bridge maintenance cycle
0
500 cycles
1
1000 cycles
2
1500 cycles
3
2000 cycles
4
2500 cycles
5
3000 cycles
6
3500 cycles
7
4000 cycles
8
4500 cycles
9
5000 cycles (default setting)
10
5500 cycles
11
6000 cycles
93
Cycle counter outputloading bridge cycles
18 - EN
Menu 9 Service menu
menu
Entry
Selection
item
94
Preselection of the door sealing maintenance cycle
0
500 cycles
1
1000 cycles
2
1500 cycles
3
2000 cycles
4
25000 cycles
5
3000 cycles
6
3500 cycles
7
4000 cycles
8
4500 cycles
9
5000 cycles (default setting)
10
5500 cycles
11
6000 cycles
95
Cycle counter output door sealing cycles
96
Operating hours counter output – hours
97
Error memory output hours – error code
98
Software version output – serial number – creation
date
99
Reset to default setting
Press for 5 s
- -
Exit menu
7

Operation

Safety instructions for operation
Observe the following safety information for operation:
The operator must be instructed on how to handle the
control or the controlled loading bridge and be familiar with
the applicable safety regulations.
Comply with the accident prevention regulations and
general safety regulations relevant to the field of application.
Check the control and the controlled loading bridge for
visual defects before use.
If you detect any safety-relevant deficiencies, decommission
the loading bridge and report all defects to the responsible
line manager.
Have the deficiencies remedied immediately.
If the operational behaviour of the loading bridge changes,
switch the system off immediately. Recommissioning must
be prevented. Notify the operating company of the change.
Crush hazard by moving loading bridge
WARNING
Limb crush hazard when moving loading bridge.
Tripping or falling hazard when loading!
CAUTION
With the control switched off, triggered emer-
gency stop switch or active restart lock, the float-
ing position of the loading bridge is not active
and the vertical movements of the truck are not
balanced out.
TAR1 400V / 230V
The loading bridge must be visible from the
place of operation.
During lifting and lowering the loading
bridge, it is not permitted to persons to be in
the travel path of the loading bridge.
It is not permitted to drive on the loading
bridge until restart.