Descargar Imprimir esta página

Osmofilter TM68 Manual De Usuario página 63

Ocultar thumbs Ver también para TM68:

Publicidad

Idiomas disponibles

Idiomas disponibles

14.
TROUBLESHOOTING
PROBLEM
6. Chlorides in
Inadequate regeneration.
outlet water
Resin dirty.
(salty taste).
7. Iron in the
Resin dirty.
outgoing water.
Excessive refill time.
Excessive inlet pressure.
8. Excess water
Insufficient brine suction.
or overflow in the
salt deposit.
Obstruction of the salt valve.
Inadequate injector.
Blocked programmer.
Inlet water pressure insufficient.
Air in the brine suction line.
9. The softener
does not suction
Exit to drain blocked.
the brine
Aspiration valve / probe
blocked.
Injector blocked.
10. Continuous
The programmer does not
regeneration.
function correctly.
Internal leak on valve.
Power supply cut during
11. Continuous
backwash or quick wash
drainage of water
into the drain or
Dirtiness inside valve.
salt tank.
Adjustment of the ceramic disc.
Valve blocked.
12. Equipment
Failure in the electric connection.
doesn't perform
Faulty programmer.
a bed filter
Temporal power suppy cut.
cleaning
There is air in the equipment.
Too much flow on Backwash
13. Water leakage
cycle.
in drain outlet.
Crepina superior dañada.
Failure of electronic board.
14. Toothed gear
Internal wires desconected.
turns constantly.
Toothed gear damaged.
ORIGIN
SOLUTION
Increase the quick wash duration.
Sanitize tank. Contact with TS.
Check regeneration cycles. Increase the quick
wash duration. Sanitize. Contact with TS.
Correct refill time. Contact with TS.
Reduce pressure to 4 bar. Contact installer or TS.
See point 9.
Contact with TS.
Contact with TS.
Contact with TS.
Increase pressure to 2 bar minimum.
Tighter connections in the suction line and verify
seal. Contact with TS.
Check and/or clear drain outlet.
Clean probe/valve. Contact with TS.
Contact with TS.
Change the programmer. Contact with TS.
Replace valve main body.
Set the by-pass in position closed until power
supply is back.
Contact with TS.
Contact with TS.
Contact with TS.
Check the electrical installation.
Replace the programmer. Contact with TS.
Reprogram the current time.
Evacuar totalmente el aire del tanque.
Change the DLFC.
Replace the upper crepine.
Replace electronic board and display.
Check internal wires.
Repair toothed wheel.

Publicidad

loading

Este manual también es adecuado para:

Tm69Tm69 led