Operating data
a)
measurement category according to IEC 61010-1 ...................... CAT IV 600 V (III 1000 V)
b)
type of insulation ........................................................................................... double, Class II
c)
housing type .............................................................................................. double-composite
d)
degree of housing protection acc. to EN 60529 ............................................................. IP40
e)
pollution degree .................................................................................................................... 2
f)
opening of measurement clamp ........................................................................ 48 mm (1.9")
g)
power supply of the meter ............................... Li-Pol 7.4 V 1200 mAh rechargeable battery
h)
diode test ..................................................................................... I = 1.5 mA, U
i)
continuity test ............................................................................ acoustic signal for R < 50 Ω
.................................................................................................... measuring current <0.5 mA
j)
indication for range exceeding .............................................................................OL symbol
k)
low battery indication ........................................................................................ symbol
l)
measurement rate ...................................................................3 measurements per second
m)
INRUSH function
▪ sampling time ............................................................. 37.5 Hz (RMS), 2.4576 MHz (clock)
▪ integration time......................................................................................................... 100 ms
n)
VFD function
▪ maximum operating voltage ......................................................... 1500 V DC / 1000 V AC
o)
HVDC function
▪ maximum operating voltage .................................... specified by the high-voltage adapter
p)
range of the non-contact voltage detector .............................. 100...1000 V AC (50/60 Hz)
q)
response time for PEAK function .................................................................................. 1 ms
r)
temperature sensor .............................................................................. type K thermocouple
s)
input impedance
▪ V AC ............................................................................................................................ 9 MΩ
▪ V DC .......................................................................................................................... 10 MΩ
t)
AC read-out ...............................................................................True RMS (A AC and V AC)
u)
AC bandwidth .................................................................................................... 50...1000 Hz
v)
display .......................................................................................... backlit LCD with bargraph
w)
dimensions ................................................................................................. 273 x 96 x 48 mm
x)
meter weight .................................................................................................................. 490 g
y)
operating temperature ........................................................................................... +5..+40C
z)
operating humidity ........................................................................................................ < 80%
aa) storage temperature ............................................................................................. -20..+60C
bb) storage humidity ........................................................................................................... < 80%
cc) maximum operating altitude ....................................................................................... 2000 m
dd) Auto-Off function ................................................................................................. 15...60 min
ee) compliance with the requirements of the following standards ............................EN 61326-1
ff)
quality standard ...................................................................................................... ISO 9001
CMP-1015-PV – USER MANUAL
< 3.3 V DC
0
73