Descargar Imprimir esta página

Priming; Oil Details; Hyspin® Vg 32 And Aws Oil Safety Data; Waste Disposal - Stanley Genesis 07537 Traducción De Instrucciones Originales

Ocultar thumbs Ver también para Genesis 07537:

Publicidad

Idiomas disponibles

Idiomas disponibles

O R I G I N A L I N S T R U C T I O N

7. PRIMING

Priming is ALWAYS necessary after the tool has been dismantled and prior to operating. It may also be necessary to restore the full
stroke after considerable use, when the stroke may be reduced and fasteners are not fully placed by one operation of the trigger.

7.1 OIL DETAILS

The recommended oil for priming is Hyspin® VG 32 available in 0.5l (part number 07992-00002) or one gallon containers
(part number 07992-00006).
Please find specific table and safety data below.
7.2 HYSPIN® VG 32 AND AWS OIL SAFETY DATA
First Aid
SKIN:
Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention. Short term
contact requires no immediate attention.
INGESTION:
Seek medical attention immediately. DO NOT induce vomiting.
EYES:
Irrigate immediately with water for several minutes. Although NOT a primary irritant, minor irritation may occur following
contact.
Fire
Flash point: 232°C. Not classified as flammable.
Suitable extinguishing media: CO
Environment
WASTE DISPOSAL: Through authorised contractor to a licensed site. May be incinerated. Used product may be sent for
reclamation.
SPILLAGE: Prevent entry into drains, sewers and water courses. Soak up with absorbent material.
Handling
Wear eye protection, impervious gloves (e.g. of PVC) and a plastic apron. Use in well ventilated area.
Storage
No special precautions.

7.3 PRIMING PUMP

To enable you to follow the priming procedure opposite, you will need to obtain a priming pump 07900-00700.

7.4 PRIMING PROCEDURE

DISCONNECT THE TOOL FROM THE AIR SUPPLY OR SWITCH OFF AT VALVE 70.
All operations should be carried out on a clean bench, with clean hands in a clean area.
Care MUST be taken at all times, to ensure that no foreign matter enters the tool, or serious damage may result.
Remove Bleed Screw 85 and Bonded Seal 84.
Connect air supply to tool and switch ON/OFF Valve 70 to 'ON" position.
Invert tool over suitable container and actuate trigger. Waste oil will be ejected through the bleed screw hole.
CARE SHALL BE TAKEN TO ENSURE THAT THE BLEED HOLE IS NOT DIRECTED TOWARDS THE OPERATOR OR OTHER
PERSONNEL.
Disconnect air supply to tool or switch ON/OFF Valve 70 to 'OFF" position.
Fill the priming pump with oil.
Screw priming pump 07900-00700 into the bleed screw hole with Bonded Seal 84 in place.
Actuate the priming pump by pressing down and releasing several times until resistance is felt.
Item numbers in bold refer to the general assembly drawing and parts list on pages 19-20.
, dry powder, foam or water fog. DO NOT use water jets.
2
Ensure that the new oil is perfectly clean and free from air bubbles.
IMPORTANT
E N G L I S H
21

Publicidad

loading