Hydraulic system requirements
The following is required for an optimum performance of the hydraulic impact wrench:
Provide a volume flow of 20 to 40 l/min at an operating pressure of 70 to140 bar.
The system should not have more than 17 bar back pressure.
The hydraulic system should have sufficient heat rejection capacity to limit the maximum oil
temperature to 60°C at the maximum expected ambient temperature.
It is recommended:
That filter elements are sized for a volume flow of at least 114 lpm for cold temperature
startup and for maximum dirt holding capacity.
The hydraulic system should have a minimum of 10 to 25 micron of full-flow filtration..
Connecting the hydraulic supply to the hydraulic impact wrench
. The machine is designed for an open circuit.
Check:
The circuit type (open circuit or closed circuit), before connecting the machine.
That all hose couplings are clean, before connecting the hoses.
That there are no signs of leakage.