Position the power socket on the screw head or on the nut and start the hydraulic impact
wrench (see fig. 6).
Remove the socket
Pull the socket from the square.
Sockets being stuck can be loosened by slight beats with a rubber hammer.
Change the sockets
When inserting a socket, pay attention that it is properly seated on the square drive 7. If the
socket is not firmly fixed to the square drive, it can unscrew.
Before underwater operation
Ensure that:
- All hydraulic hoses are properly connected.
- The machine is tested for leakage and for the functioning of all parts.
Notice: Keep in mind that 10 meter water depth corresponds to 1 bar.
When working in greater depths match the diameter of the supply and exhaust hose
appropriately.
After underwater operation
Clean and dry the machine with compressed air.
Spray all moving parts with multi-oil-spray.
34
Start and stop
Fig. 6 Press or release
UNDERWATER USE