Starting Electric Start Engines; Generator Shut Down; Starting Hot Engines; Low Oil Level Shutdown System - Generac PRO iQ3500 Manual Del Propietário

Publicidad

Idiomas disponibles

Idiomas disponibles

4. See
Figure
3-2. When engine starts, rotate
OFF/ON/CHOKE Dial to ON (2). Choke
operation is reduced as OFF/ON/CHOKE
Dial is rotated towards ON.
NOTE: If engine fires, but does not continue to
run, rotate the OFF/ON/CHOKE Dial to OFF
and repeat starting instructions.
IMPORTANT NOTE: Do not overload gener-
ator or individual panel receptacles. See
3-3. If an overload occurs, the over-
Figure
load LED (A) will illuminate and AC output
ceases. To correct, see
Lights. Read
Know Generator Limits
fully.
B
Figure 3-3.Shutdown Fault

Starting Electric Start Engines

Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. See
3-2. Rotate the OFF/ON/
Figure
CHOKE Dial to CHOKE (1).
4. Switch Economy switch to OFF.
5. Push and hold OFF/ON electric start
switch in the ON position. See
(A). Release switch when engine starts.
Figure 3-4.Push and Hold Off/On Switch
6. See
3-2. When engine starts, rotate
Figure
OFF/ON/CHOKE Dial to ON (2). Choke
Owner's Manual for Portable Generator
Generator Status
A
005483
CAUTION
Figure 3-4
operation is reduced as OFF/ON/CHOKE
Dial is rotated towards ON.
NOTE: If engine fires, but does not continue to
run, rotate the OFF/ON/CHOKE Dial to OFF
and repeat starting instructions.

Generator Shut Down

Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
care-
property damage.
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. See
Dial to OFF (3).
4. Turn fuel cap OFF.

Starting Hot Engines

.
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. See
from STOP to ON. This will open the fuel
valve and permit starting.
2. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Pull rap-
idly up and away.
(000136)

Low Oil Level Shutdown System

The engine is equipped with a low oil level
sensor that shuts down the engine automati-
cally when the oil level drops below a speci-
fied level to prevent engine damage. See
Figure 3-3
oil has been filled to the proper level.
If the engine shuts down and there is sufficient
fuel, check engine oil level.

Parallel Operation

See the Parallel Kit Operator's Manual or con-
tact an IASD.
NOTE: All connections to the parallel kit
A
should be made while both inverters are
turned off and all loads disconnected.
1. Make sure the Engine Economy Switch is
in the same position on both generators.
014563
2. Make appropriate parallel connections to
the outlets on each Generac inverter as
outlined in the owner's manual supplied
with the kit.
NOTE: Do not disconnect any parallel kit con-
nections once the units are running.
CAUTION
Figure 3-2
Rotate OFF/ON/CHOKE
CAUTION
Figure
3-2. Turn OFF/ON/CHOKE Dial
(B). The engine will not run until the
(000136)
(000136)
13