Maintenance indicator
Normal
Tempera-
Off
ture
warning
indicator
Lamp
Green on
indicator
(Green
blinks
when the
lamp is
warming
up or
turning
off.)
Power
Green on/
indicator
Red on
Red
blinks
(Cooling)
Info
• If the temperature warning indicator illuminates, and the projector enters standby mode, follow the
possible solutions above and then wait until the projector has cooled down completely before plug-
ging in the power cord and turning the power back on. (At least 10 minutes.)
• If the power is turned off for a brief moment due to power outage or some other cause while using
the projector, and the power supply recovers immediately after that, the lamp indicator will illumi-
nate in red and the lamp may not be lit. In this case, unplug the power cord from the AC outlet,
replace the power cord in the AC outlet and then turn the power on again.
• The cooling fan keeps the internal temperature of the projector constant and this function is con-
trolled automatically. The sound of the cooling fan may change during operation because the fan
speed may change and this is not a malfunction.
• Do not unplug the power cord after the projector has entered standby mode and while the cooling
fan is running. The cooling fan runs for about 90 seconds.
EIP-2500_EN_PR_l
Problem
Abnormal
Red on
The internal
temperature is
(Standby)
abnormally
high.
Red on
The lamp does
not illuminate.
Time to change
the lamp.
Red on
The lamp does
(Standby)
not illuminate.
Green
The power
indicator blinks
blinks
in green when
the projector is
on.
49
Cause
• Blocked air intake
• Relocate the projector to
an area with proper
ventilation. (see page 8)
• Cooling fan
• Take the projector to your
breakdown
nearest EIKI Authorized
• Internal circuit
Dealer or Service Center
failure
(see page 61) for repair.
• Clogged air intake
• The lamp is shut
• Disconnect the power cord
down abnormally.
from the AC outlet, and
then connect it again.
• Remaining lamp life
• Carefully replace the lamp.
becomes 5% or
(See page 51.)
less.
• Take the projector to your
nearest EIKI Authorized
• Burnt-out lamp
Dealer or Service Center
• Lamp circuit failure
(see page 61) for repair.
• Please exercise care when
replacing the lamp.
• Securely install the cover.
• The lamp unit cover
• If the power indicator blinks
is open.
in green even when the
lamp unit cover is securely
installed, contact your
nearest EIKI Authorized
Dealer or Service Center
(see page 61) for advice.