1st ignition/test by the Edilkamin authorised Dealer
Start-up must be carried out as prescribed by point 3.21 of
This standard indicates the control operations to be carried out
te the boiler based on the pellet type used and the installation
conditions.
sion the boiler in order for the guarantee to be activated.
The DEALER must also:
- Verify that the hydraulic system is correctly installed and is
guarantee safety.
The presence of a tank within the boiler does NOT
guarantee appropriate protection from thermal expan-
sion occurring in the whole system.
Therefore the installer must assess whether an additio-
nal expansion tank is needed, depending on the type of
system installed.
- Connect the electrical power to the boiler and implement a
cold test (to be carried out by the DEALER).
Before igniting you must check:
tors temporarily decreases.
NOTE regarding the fuel.
CALGARY/ORLANDO is designed and programmed to burn
wood pellets with 6 mm diameter. Pellets are a type of fuel in
compressed under high pressure with no adhesives or foreign
materials. They are sold in bags of 15 kg.
will render the warranty null and void. Such use is detected
by laboratory analyses.
stoves to guarantee the best performance when pellets with
the following characteristics are used:
INSTRUCTIONS FOR USE
-
-
-
- 35
ATTENTION:
operation using the manual valves (V1 - V2 - V3) located on
the front part of the top.
and in the event the plant has only been partially reloaded. The
presence of air in the ducts does not allow for proper operation.
Rubber tubes are supplied with valves V2 and V3 to facilitate
relief operations.
PELLET
LOADING
DOOR
V2
- diameter: 6 millimetres
- maximum length: 40 mm
- maximum moisture content: 8%
stoves must be recalibrated – a similar procedure to that
malfunctions; stop the boiler-stove from functioning due to
-
V1
V3