4.1
Connector plug
7
Slewing ring
Cable routing – stationary filter unit with connection socket in the unit
1. Connect the connection cable (Pos. 4) to the unit. To do this, insert the
connector plug (Pos. 4.1.) into the connection socket (Pos. 4.2).
2. Route the connection cable (Pos. 4) through the ducting system up to
the extraction arm.
3. For further steps see chapter: Cable routing 2-4 metre extraction arm.
Cable routing – stationary filter unit with control box or transformer box
1. Connect the connection cable (Pos. 4) to the control box (Pos. D) or
transformer box (Pos. E). To do this, insert the connector plug (Pos. 4.1.)
into the connection socket provided.
2. Route the connection cable (Pos. 4) up to the pipe bend (Pos. 10) of the
cantilever (Pos. 9).
NOTE
Damage to the connection cable due to tensile stress or crushing!
When laying, make sure that the connecting cable is not subjected to
tension or crushing in the joint areas.
Leave sufficient length when laying the cable!
3. Drill a hole at the back of the pipe bend (Pos. 10) and insert a suitable
cable gland.
4. Pull the connecting cable (Pos. 4) through the cable gland, ducting
system, slewing ring to the extraction arm.
5. For further steps see chapter: Cable routing + connection of the
extraction hood with lighting.
1502760-03
9
10
Tab. 29: Positions on the product
- 66 -
Pipeline
Pipe bend
EN