NOTE
Electronic storage media can be corrupted or erased
The integral magnets in the B.Box Evo Stand and some of the cable connectors are very
strong. Electromagnetic fields can disrupt the functions of storage media (e.g., credit and
EC cards, data carriers) and can erase their contents.
z Keep storage media of this kind away from the magnets.
Property damage due to maintenance and repairs by unauthorized personnel
Repairs and maintenance activities performed by unauthorized and / or unqualified
individuals may result in material damage to the device.
z Maintenance and repair work may only be carried out by authorized personnel.
There are no user-replaceable parts and no maintenance is required during
the service life of the system.
2.4 Medical notes
2.4.1 Medical notes on PEMF
In case of atypical reactions to the PEMF therapy, a doctor should be consulted.
For conditions requiring immunosuppression that are not related to transplantation, e.g.,
autoimmune diseases or dermatological diseases, there are no contraindications for use of
the PEMF therapy.
At the end of the first cycle, new users who regularly take blood thinning/anticoagulant agents
or antihypertensive medications are advised to consult their attending physician to check for
any change in their effectiveness.
If the following circumstances or complaints exist, the prior approval of the attending physician/
specialist must be obtained before application of the PEMF therapy:
Unexplained fever
Infectious diseases
Severe cardiac rhythm disorder
Severe psychosis
Uncontrolled seizure disorders (e.g., epilepsy)
Long-term use of β-recepter antagonists
Use of high-dose corticoid agents
20
Long-term use of anticoagulants (coumarin derivatives)
Ongoing use of prescription medications
Pregnancy
Tumor diseases
2.4.2 Medical notes on LLLT
In case of atypical reactions to LLLT, a doctor should be consulted.
If the following circumstances or complaints exist, the prior approval of the attending physician/
specialist must be obtained before application of LLLT:
Light-induced seizures (light sensitivity)
Light-induced migraine headaches
Ingestion or application of ointments (cosmetics), medications, or supplements known to
cause photosensitivity
Ongoing use of prescription medications
Allergic reaction caused by light
Tumor diseases
Cancerous lesions on the skin
Skin lesions caused by bacteria, viruses or fungi
ES
NL
IT
FR
21
DE
EN