Put the switch on the SWR-meter to position FWD (calibration).
Press the PTT "push-to-talk" switch (12) on the microphone to transmit.
-
-
Bring the index needle to  by using the calibration key.
-
Change the switch to position REF (reading of the SWR level). The reading on
the Meter should be as near as possible to 1. If this is not the case, readjust
your antenna to obtain a reading as close as possible to 1. (A SWR reading
between 1 and 1.8 is acceptable).
-
It will be necessary to recalibrate the SWR meter after each adjustment of
the antenna.
WARNING: In order to avoid any losses and attenuations in cables used for
connection between the radio and its accessories, PRESIDENT recommends
to use a cable with a length less than 118.11 inches (3 m).
Your transceiver is now ready for use.
B) HOW TO USE YOUR TRANSCEIVER
1) ON/OFF ~ VOLUME
Turn on : turn VOL knob (1) clockwise. If the function KEY BEEP is active (see
menu KEY BEEP page 12), the radio emits a beep. The radio is "on".
Display briefly shows the microphone type (consult the MICROPHONE TYPE
menu page 13).
Turn Off : turn VOL knob (1) counterclockwise until radio emits click sound.
Your radio is "off".
Volume Adjustment: rotate VOL knob (1) clockwise to increase the volume.
Turn the same knob counterclockwise to reduce the sound level.
2) ASC (Automatic Squelch Control) ~ SQUELCH
Suppresses undesirable background noises when there is no communication.
Squelch does not affect neither sound nor transmission power, but allows a
considerable improvement in listening comfort.
a) ASC: AUTOMATIC SQUELCH CONTROL
Worldwide patent, a PRESIDENT exclusivity.
Turn the SQ knob (2) anti-clockwise into ASC position.
No repetitive manual adjustment and a permanent improvement between
the sensitivity and the listening comfort when ASC is active. This function can
be disconnected by turning the switch clockwise. In this case the squelch
adjustment becomes manual again.
appears on LCD.
disappears from LCD.
7
b) MANUAL SQUELCH
Turn the SQ knob (2) clockwise to the exact point where all background
noise disappears. This adjustment should be done with precision as, if set
to maximum (fully clockwise), only the strongest signals will be received.
3) LCD
Messages part }
Indicates transmission
PA
PA (Public Address) mode selected
AM
AM mode selected
FM
FM mode selected
SCN
SCAN function activated
VOX
VOX function activated
EMG
Emergency channel (1 or 2) is activated
Automatic Squelch Control activated
LOCK function activated
ANL
ANL filter is activated
NB
NB filter is activated
HIC
HI-CUT filter is activated
Noise Gate filter is activated
NRC filter is activated
TALKBACK
TALKBACK function activated
ROGER BEEP function activated
BP
KEY BEEP function activated