Descargar Imprimir esta página

BONFIGLIOLI Vectron ANG210 Manual Del Usuario página 137

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

8.7
Size 5 ANG410 (18.5 to 30.0 kW, 400 V)
Type
ANG410
Size
Output, motor side
Recommended motor shaft power
Output current
Long-term overload current (60 s)
Short-time overload current (1 s)
Switching frequency
Output, braking resistor
Min. braking resistance
Recommended braking resistor
(U
= 770 V)
dBC
Input, mains side
Mains current
2)
Fuses
UL type 600 VAC RK5
Mechanical
Dimensions
Weight approx.
Connection terminals
Ambient conditions
Energy dissipation (2 kHz switching
frequency)
Output current (Maximum current in continuous operation)
Frequency inverter nominal power
18.5 kW
22 kW
30 kW
1)
Connection requires a commutating choke.
2)
Mains current with relative mains impedance ≥ 1% (see „Electrical installation")
07/20
P
kW
I
A
I
A
I
A
f
kHz
R
Ω
R
Ω
I
A
I
A
I
A
HxWxD mm
m
kg
A
mm
2
P
W
Quick Start Guide ANG
-27
-29
5
18.5
22.0
40.0
45.0
60.0
67.5
80.0
90.0
2, 4, 8
16
26
22
42.0
50.0
50
50
250x200x260
8
up to 25
445
535
Switching frequency
2 kHz
4 kHz
40.0 A
40.0 A
45.0 A
45.0 A
1)
1)
60.0 A
60.0 A
-31
30.0
60.0
90.0
120.0
GB
16
58.0
1)
63
60
605
8 kHz
40.0 A
45.0 A
1)
60.0 A
137

Publicidad

loading

Este manual también es adecuado para:

Vectron ang410Vectron ang510Vectron ang610