Notes on operating under mfx
• No address is required under mfx; each decoder receives a
non-recurrent and unique identifier (UID).
• The decoder automatically logs on to a Central Station or
Mobile Station with its UID and name.
• Name ex works: Stw Koblenz
• The settings of the decoder can be programmed via the
graphical interface of the Central Station or also in part with
the Mobile Station.
CV
Discription
1
Address
4
Braking delay
8
Reset
17
Extendet address (upper part) (CV 29, Bit 5=1)
18
Extendet address (lower part) (CV 29, Bit 5=1)
Bit 0: Travel direction polarity reversal
Bit 1: number of speed levels 14 – 28/126
29
Bit 2: Analog operation on/off
Bit 5: address size 7 Bit / 14 Bit
Multiple Unit Combination with the Central Station 3 under mfx
Call up the locomotive menu in the Central Station 3 and select
„Create M.U. Combination". Assign a unique name for the M.U.
combination and then drag the desired unit from the locomotive
list into the open field. After you have confirmed the selection,
the M.U. combination will appear in the locomotive list with the
image of the lead unit.
Factory
DCC Value
Setting
1 – 127
3
1 – 71
5
8
131
0 – 255
195
0 – 255
242
0 – 255
6
7