Descargar Imprimir esta página

SICK WS24-2 Manual De Instrucciones página 8

Ocultar thumbs Ver también para WS24-2:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 80
OPERATING INSTRUCTIONS
5
Electrical installation
en
8
O P E R A T I N G I N S T R U C T I O N S | WS/WE24-2
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Plug connection: note pin assignment: when the lid is open, the male connector
can be swiveled horizontally and vertically.
Terminal connection: Note the permissible cable diameter of 5 to 10 mm. When
the lid is open, the M16 connector can be swiveled horizontally and vertically.
Unscrew the M16 connector and remove sealing plug. Lead voltage-free supply
cable through and connect sensor in accordance with
Retighten M16 connector with seal so that the IP enclosure rating of the device is
ensured.
Figure 2: Opening the sensor
Only apply voltage/switch on the power supply once all electrical connections have
been established.
Explanation of the connection diagram (Tables 2-8) which are divided up into DC and
AC/DC devices:
Alarm = alarm output (see
n. c. = not connected
NC = normally closed
NO = normally open
Q / Q = switching outputs
TE/Test = test input (see
table 2
Figure 3: Electrical connection
table 2
and
Additional
functions)
and
table
8)
table 2
and
table
5.
8008782.1DMA/2022-07-12 | SICK
Subject to change without notice

Publicidad

loading

Este manual también es adecuado para:

We24-2