1 DEVICENET CONNECTOR
Pin
Signal
1
GND BUS
2
CAN_L
3
Cable shield
4
CAN_H
5
+24V BUS
2 CONFIGURATION SWITCH
S1
S2
Baudrate
OFF
OFF
125k
OFF
ON
250k
ON
OFF
500k
ON
ON
(Reserved)
4 STATUS INDICATORS
A NOT USED
B NETWORK STATUS
OFF
GREEN
GREEN flashing
RED
RED flashing
Alternating RED, GREEN
C MODULE STATUS
OFF
GREEN
GREEN flashing
RED
RED flashing
Alternating RED, GREEN
D NOT USED
Consul the site: http://www.anybus.com/support/support.asp?PID=72&ProductType=Anybus-S
Document: Fieldbus Appendix
40
S3
S4
S5
S6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
...
...
...
...
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
No power, not on-line
On-line, one or more connections established
On-line, no connections established
A major unrecoverable fault has been detected
One or more connections timed out
Self-test in progress
No power
Normal operation
Auto test in progress
A major fault has been detected
A minor fault has been detected
Self-test in progress
S7
S8
Mac ID
OFF
OFF
0
OFF
ON
1
ON
OFF
2
ON
ON
3
...
...
...
OFF
OFF
60
OFF
ON
61
ON
OFF
62
ON
ON
63