Chapter 6
Page 20
6
Fault Detection and Troubleshooting
6.1
Security Measures
DANGER
WARNING
6.2
Notes on Troubleshooting
Please contact our service partners in case of malfunctions and complaints within the warranty period. Even
after the warranty period is expired you can have necessary repair work done by our service partners and
certified electricians.
Service work should only be carried out by authorised specialist staff.
Defective components should only be replaced with
the replacement of individual components.
In the event of after-sales service and when ordering spare parts specify always the data and corresponding
part number given in the rating plate.
Regular inspection and maintenance of the appliance prevent disruptions to operation and ensure safety.
6.3
Fault and Action Table
Fault
Running noise of swivel casters
Appliance does not become warm;
indicator light does not come on
Appliance becomes warm; indicator
light does not come on
Mobile Cutlery Soak Sink
BTH/60-60
All manuals and user guides at all-guides.com
Hazardous electrical voltage
The electrical voltage may be considerably dangerous to limb and life of per-
sons and lead to injuries.
Before looking for faults, switch off the appliance at the mains. Pull out the
mains plug and hung it on the plug holder provided.
Risk of hot surfaces
The heated appliances can become hot during operation and only cool down
slowly in the air.
Before looking for faults open the door of the appliance and let it cool down
sufficiently.
HUPFER
Possible cause
Defective caster bearings
Sticky surface of the casters
Defective building fuses
Defective On / Off switch
Defective mains connecting lead or
mains plug
Defective indicator light
Defective circuit
Fault Detection and Troubleshooting
®
original parts. The modular design simplifies
Action
Replace the swivel casters.
Clean the swivel casters with water.
Check fuse and repair, if necessary
Switch off the appliance at the mains,
have it checked and repaired by
authorised specialist staff, if neces-
sary
Switch off the appliance at the mains,
have it checked and repaired by
authorised specialist staff, if neces-
sary
Take the appliance out of operation,
have it checked and repaired by
authorised specialist staff, if neces-
sary.
Take the appliance out of operation,
have it checked and repaired by
authorised specialist staff, if neces-
sary.