supplied with the boiler, order it exclusively
from CLIMIT .
The power supply must be single-phase
230V - 50 Hz through a main switch pro-
tected by a fuse with a distance of at least 3
mm between contacts .
NOTE: The boiler must be connected with
an efficient grounding system . CLIMIT shall
not be held liable for injury or damage
resulting from failure to ground the boiler .
ATTENTION: Before every intervention on
the boiler, cut off the electricity supply by
means of the main switch of the system,
since even if the boiler is "OFF", the electri-
cal panel remains connected to the electri-
city .
2 .11 .1
Chronothermostat
connection
Remove the boiler casing, tilt the control
2 .11 .4
Use with different
electronic systems
Some examples are given below of boiler
systems combined with different electronic
systems . The electrical connections to the
boiler refer to the wording on the diagrams
(figs . 13-13/a) . The zone valve control starts
at every demand for heating of the remote
control .
Description of the letters indicating the
components shown on the system dia-
grams from 1 to 6:
M
C .H . flow
R
C .H . return
CR
Remote control CR 63
SE
External temperature sensor
TA 1-2
Zone room thermostat
VZ 1-2
Zone valve
RL 1-2
Zone relay
Sl
Hydraulic separator
P 1-2
Zone pump
IP
Floor system
EXP
Expansion card
(code 6301430)
VM
Thermostatic mixer valve
TSB
Safety thermostat low
temperature
panel and connect the chronothermostat
to the 6 pole terminal board as indicated in
the boiler electrical diagram (see paragraph
2 .12) after having removed the existing bri-
dge .
The chronothermostat to be used must be
of a class conforming to the standard EN
60730 .1 (clean electrical contact) .
2 .11 .2 Remote control CR 63
connection (optionals)
The boiler is designed for connection to a
remote control unit CR 63 code 8092219
coupled to an optional expansion kit code
8092240 .
The remote control unit allows for complete
remote control of the boiler, except release
of the boiler .
Whenn the connection has been made the
boiler display will show the following mes-
1
BASIC SYSTEM
SYSTEM WITH A DIRECT ZONE AND ROOM THERMOSTAT, OR WITH A
REMOTE CONTROL (Code 8092219), KIT EXPANSION REMOTE CONTROL
(Code 8092240) AND EXTERNAL SENSOR (Code 8094101)
SE
TA
sage: Cr .
For installation and use of the remote con-
trol, follow the instructions in the package .
2 .11 .3
External sensor connection
(optional)
The boiler is designed for connection to an
external temperature sensor, supplied on
request (code 8094101), which can auto-
matically regulate the temperature value of
the boiler output according to the external
temperature .
For installation, follow the instruction in the
package . It is possible to make corrections
to the values read by the drill acting on the
PAR 4 .
3 .4
EXTERNAL SENSOR (fig . 15)
If there is an external sensor, the heating
settings SET can be taken from the climatic
CR
EXP
R
M
IT
ES
ENG