4
Technical data
Max. charging power [kW]
Rated current I
[A]
nA
Rated current of a charging point
Mode 3 I
[A]
nC
Max. back-up fuse [A]
Conditional rated short-circuit
current I
[kA]
cc
* For the design of the maximum back-up fuse, the regulations applicable at the installation site must be
observed.
AMTRON® Compact 2.0s 11, AMTRON® Compact 2.0s 22
Connection
Nominal voltage U
[V] AC ±10 %
N
Nominal frequency f
[Hz]
N
Nominal insulation voltage U
Nominal impulse withstand voltage U
Nominal diversity factor RDF
Types of system earthing
EMC classification
Protection class
IP rating
Overvoltage category
Mechanical impact protection
Contamination rating
Installation
Stationary / movable
Use (according to IEC 61439-7)
External design
Dimensions H x W x D [mm]
Weight [kg]
Standard
The specific standards according to which the product was tested can be found in the declaration of con-
formity for the product. The declaration of conformity can be found on our website in the download section
for the selected product.
AMTRON® Compact 2.0s 11
11
16
16
20 *
1.1
[V]
i
[kV]
imp
AMTRON® Compact 2.0s 22
22
32
32
40 *
1.8
single phase / three phase
230 / 400
50
500
4
1
TN / TT (IT under certain conditions)
A+B
I
IP 44
III
IK10
3
Outdoor or indoor
Stationary
AEVCS
Wall mounted
360.5 x 206.9 x 145.6
4.7 (for products with 11 kW); 6.4 (for products
with 22 kW)
IEC 61851, IEC 61439-7
EN
11