Service And Repairs - Metabo HPT C 12RSH2 Instrucciones De Seguridad Y Manual De Instrucciones

Tronzadora radial abatible
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7.
Lubrication
Lubricate the following sliding surfaces once a month to keep the power tool in good operating
condition for a long time (see Fig. 1 and Fig. 2). Use of machine oil is recommended.
Oil supply points:
* Rotary portion of hinge
* Rotary portion of vise assembly
* Rotary portion of holder (A)
8.
Cleaning
Duct
Air gun
CAUTION:
In the operation and maintenance of power tools, the safety regulations
and standards prescribed in each country must be observed.

SERVICE AND REPAIRS

All quality power tools will eventually require servicing or replacement of parts because of wear
from normal use. To assure that only authorized replacement parts will be used and that the
double insulation system will be protected, all service (other than routine maintenance) must be
performed by an AUTHORIZED metabo HPT POWER TOOL REPAIR CENTER ONLY.
NOTE:
Specifi cations are subject to change without any obligation on the part of
metabo HPT.
Fig. 55
Clean the machine, duct and lower
guard by blowing with dry air from
an air gun or other tool.
Periodically remove chips, dust
and other waste material from the
Lower Guard
surface of the power tool, especially
from the inside of the lower guard
with a damp, soapy cloth. To avoid
a malfunction of the motor, protect it
from contact with oil or water.
If the laser line becomes invisible
due to chips and the like adhered
onto the window of the laser
marker's
wipe and clean the window with a
dry cloth or a soft cloth moistened
with soapy water, etc.
English
light-emitting
section,