G PLUS HOOD EXTRACTOR HOOD
Dear client,
We are certain that the acquisition of our extractor hood will
fully satisfy your needs. Please read the instructions contai-
ned in the manual carefully in order to get ideal results from
the use of your hood.
IMPORTANT
In order for the warranty to be effective, you must present the
sales receipt for the hood with the warranty certificate.
Without the receipt, the warranty will not be effective.
INSTALLATION, MAINTENANCE AND INSTRUCTIONS
FOR USE
GENERAL INSTRUCTIONS
Before installing and using the hood, be sure that the volta-
ge (V) and frequency (Hz) indicated on the features plate
coincide with the voltage and frequency at the place of ins-
tallation.
The features plate and technical data are located inside the
product.
INSTALLATION
The hood may be installed to work in two different ways: If
there is a possibility of installing the hood with an evacuation
pipe to the outside, it will be used in aspirating version. If this
possibility does not exist, the hood will be used in teh filte-
ring version, recirculating the air using active carbon filters.
Aspiration
If the hood is used in the ASPIRATING version, connect the
plastic conic outlet piece supplied with the hood (125 mm
diameter) to an evacuation pipe connected directly to the
outside (Fig. 1).
We recommend the use of a 125 mm. diameter pipe for bet-
ter hood performance and lower noise levels.
Filter
This hood can be transformed into an air filter if there is no
possibility of connecting it to the outside.
In this case, the air circulates through opening which you
must drilled into the furniture. In order to operate as an air fil-
Página 20
ENGLISH
ter, you must use two active carbon filters which are supplied
as separate accessories. The active carbon filters must be
replaced periodically in order to work properly, at least every
three months (depending on how frequency the filter is used)
(Fig. 4).
IMPORTANT: Do not connect the hood to smokestacks,
aeration pipes or hot air conduits. Before connecting to
pipes, consult the municipal ordinances on outgoing air and
obtain permission from the person responsible for the buil-
ding. Make sure that there is adequate ventilation, even
when the hood is being used simultaneously with another
product.
•
Never have a lighted flame under the extractor hood.
•
The appliance must be placed in such a way, that the
supply plug is accessible.
Mounting and fastening to the furniture
– The accessories needed to install the hood are located
inside the hood.
– The hood must be installed at least 66 cm. from the stove-
top.
– The screws needed to fasten the hood are contained in the
bag of accessories which comes with the hood. (Fig. 2).
Electrical Connection
Connect the cable to an oulet or an omnipolar switch which
must have a contact aperture distance of at least 3 mm.
The manufacturer will not be responsible if all necessary and
current safety norms for the correct and normal operation of
the electrical part are not observed.
The hood complies with European Directives EG No. 76/889
EEC and 82/499 EG on protection against radial interference.
CONTROL PANEL - GT PLUS
This panel is located on the lower part of the hood and
includes:
– 4 position switch which control the motor (OFF, 1st, 2nd,
and 3rd speed) (Fig. 5, ref. A).
– Control lamp for motor operation (Fig. 5, ref. B).
– Light switch (Fig. 5, ref. C).
CONTROL PANEL - LGT PLUS
This panel is situated on the front of the extractor and
includes:
- 3 control switches for the motor (speed positions 1, 2 and
3) (ref W)
- Off button of the motor (ref V)
- On/off light of the motor (ref T)
- Light switch (ref. U)
MAINTENANCE
– Cleaning.
Prior to any cleaning operation, be sure that the electric
cable is disconnected and that the switch is in the off posi-
tion. Clean the outside of the hood with a non-corrosive
liquid detergent and avoid the use of abrasive cleaning
products.
– Changing the light bulbs.
Before changing the light make sure that the hood is not
connected.
Remove the grease filter and replace the light with a light
bulb no more powerful than that specified in the Technical
Characteristics. Place the filter in position.
IMPORTANT WARNING FOR EXTRACTOR HOODS
WITH HALOGEN LAMPS
If the halogen lamps have to be replaced, they must be
replaced by lamps with an aluminium reflector, never
dichroic lamps, to avoid unnecessary overheating in the
lamp holders.
– Cleaning the grease filter.
Depending on usage, but at least once a month, the grea-
se filters should be disassembled (Fig. 3) and cleaned in a
dishwasher or in soap and hot water. If cleaned in a dish-
washer, we recommend placing them vertically to prevent
food remains from being deposited on them. Once they
have been rinsed and dried, reinstall them by reversing the
procedure used for disassembly.
IMPORTANT
Never leave frying food unattended since the oil can overhe-
at or catch fire. When frying with oil which has been used
previously, the risk of fire is even greater. Never use the hood
where there are other devices with discharges connected to
the outside unless the perfect ventilation of the area can be
guaranteed.
To avoid the possibility of fire, all of these recommendations and
the periodic cleaning of the filters should be strictly observed.
THE MANUFACTURER DECLINES ANY LIABILITY IF THE
INSTRUCTIONS FOR THE INSTALLATION, MAINTENAN-
CE AND USE OF THE EXTRACTOR HOOD ARE NOT
FOLLOWED.
If the electrical cable becomes damaged it must be
changed by an official distributor.
CATA ELECTRODOMÉSTICOS, S.L. reserves the right to
effect any technological improvement or modification
without prior notice.