1.3
TECHNICAL FEATURES
Model
Heat output
Nominal (80-60°C)
Nominal (50-30°C)
Reduced G20 (80-60°C)
Reduced G20 (50-30°C)
Reduced G31 (80-60°C)
Reduced G31 (50-30°C)
Heat input nominal
Heat input reduced G20/G31
Max./min. useful yield (80-60°C)
Max./min. useful yield (50-30°C)
Useful yield at 30% of the load (40-30°C)
Termal efficiency (CEE 92/42 directive)
Losses after shutdown to 50°C (EN 483)
Supply voltage
Adsorbed power consumption
Electrical protection grade
C.H. setting range
Water content boiler
Maximum water head
Maximum temperature
Capacity of the heating expansion vessel
Pressure of the heating expansion vessel
D.H.W. setting range
D.H.W. flow rate (EN 625)
Continuous D.H.W. flow rate ∆t 30°C
D.H.W. pressure min/max
Water content mini reservoirs
Smokes temper. at max. flow rate (80-60°C)
Smokes temper. at min. flow rate (80-60°C)
Smokes temper. at max. flow rate (50-30°C)
Smokes temper. at min. flow rate (50-30°C)
Min./max. smokes flow
CO
at max./min. flow rate G20
2
CO
at max./min. flow rate G31
2
CE certification
Category
Type
NOx emission class
Weight
Main burner nozzle
Quantity nozzles
G20/G31 nozzle diameter
Consumption at max./min. flow rate
G20
G31
Gas supply pressure
G20/G31
FORMAT DGT HE 25/15
kW
kW
kW
kW
kW
kW
kW
kW
%
%
%
W
V-Hz
W
IP
°C
l
bar
°C
l
bar
°C
l/min
l/min
bar
l
°C
°C
°C
°C
kg/h
%
%
B23P-53P/C13-33-43-53-83
kg
ø
m
3
/h
kg/h
mbar
19,5
20,7
5,7
6,3
6,6
7,3
20/24
6,0/7,0
95,2/97,5
105,2/103,7
107,5
100
230-50
125
X5D
20/80
7, 1 5
3
85
6
1,2
10/60
11,3
11,7
0,5/7,0
15
75
56
57
39
10/35
9,0/9,0
10,0/10,0
1312BT5266
II2H3P
5 (< 30 mg/kWh)
45
1
7,0/5,0
2,54/0,63
1,86/0,54
20/37