5.2.2 Standard components
Fig. 1: Product overview
1 Device plug
3 Control buttons
5.2.3 AS variant
M12x1
A
B
35,5
B2
73
Fig. 2: Dimensions of AS variant sensor filter combination
A IO-Link
* Internal thread
Table 5: Dimensions of AS variant sensor filter combination
D1
D2
AS2-AF2-G038
15.0
G3/8"
AS3-AF2-G012
18.6
G1/2"
AS5-AF2-G100
30.3
G1"
AVENTICS™ AF2 | R412026496–BAL–001–AB | English
1
2
3
2 Display
B1
45,5
*)
M12
A
**)
A
B Ethernet
** Flow direction
H1
H2
H3
H4
163.5
65
34.0
62
189.5
80
42.5
75
250.0
109
58.0
102
5.2.4 HF variant
B
B
Fig. 3: HF variant sensor dimensions
A IO-Link
D1 Inside diameter
D3 External diameter
Table 6: HF variant sensor dimensions
Nominal width
B1
B2
DN40
104
31.5
DN50
126
38.5
170
52.0
5.2.5 Function and application
The flow sensor uses the calorimetric measuring principle. The sensor measures
the cooling effect of the medium flowing over the heated probe.
The higher the flow speed of the medium, the higher the cooling effect of the
heated probe.
In the IO-Link variant, the sensor has two configurable switch outputs Q1 and Q2
for flow, pressure, or temperature. Additionally, an IO-Link interface is provided
at switch output Q1.
The flow sensor is particularly suited for the following purposes:
• Measuring compressed air and non-corrosive and non-ignitable gases in ma-
chines
• Monitoring the energy consumption of compressed air on machines and in
the pressure distribution system
• Monitoring leaks in compressed air lines on machines
• Measuring inert gases in the packaging of foodstuffs
5.3 Identification
Product identification
The ordered product is clearly identified by the material number.
Check the material number to determine whether the delivered product matches
the number on your order confirmation or delivery note.
The material number can be found in these locations:
• On the name plate.
Ø D1
Ø D2
45,5
B Ethernet
D2 Inside diameter
L1 Height
Ø D1
Ø D2
Ø 42.1 ± 0.7
Ø 41.1 ± 0.1
Ø 53.1 ± 0.7
Ø 54.1 ± 0.1
Ø D3
A: 18
B: 14,5
Ø D3
L1
Ø 48.3 ± 0.3
80 ± 2
Ø 60.3 ± 0.3
86 ± 2
26