Disposal And Recycling - Stanley D 210/8/6 Manual De Instrucciones

Ocultar thumbs Ver también para D 210/8/6:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
hours in service. A clogged intake filter will decrease the
compressor's performance dramatically. Remove the
filter from the compressor and undo the thumb screw
on the air filter. You can then remove the filter from the
two halves of the plastic housing, tap it to remove the
dirt, blast it down with low-pressure compressed air
(approx. 3 bar) and re-insert it (Fig. 9).
6.8 Storage
Warning!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
8. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
Leakage of air from the valve
of the pressure switch with the
compressor off.
Reduction of performance.
Frequent start-up. Low pressure
values.
The compressor stops and
restarts automatically after a few
minutes.
In the V, 3 HP versions, it is does
not start.
After a few attempts to restart,
the compressor stops.
The compressor does not stop
and the safety valve is tripped.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts.
Tampering with the machine may impair its safety and in any case make the warranty null and void.
secured in such a way that it cannot be started up
again by any unauthorized person.
Warning!
Store the compressor only in a dry location which
is not accessible to unauthorized persons. Always
store upright, never tilted!

7. DISPOSAL AND RECYCLING

The unit and its accessories are made of various types
of material, such as metal and plastic. Defective com-
ponents must be disposed of as special waste. Ask
your dealer or your local council.
CAUSE
Check valve that, due to wear
or dirt on the seal, does not
perform its function correctly.
Excessive performance request,
check for any leaks from the
couplings and/or pipes. Intake
filter may be clogged.
Tripping of the thermal cutout
due to overheating of the motor.
Tripping of the thermal cutout
due to overheating of the motor
(removal of the plug with the
compressor running, low power
voltage).
Irregular functioning of the
compressor or breakage of the
pressure switch.
27
REMEDY
Unscrew the hexagonal head of
the check valve, clean the valve
seat and the special rubber disk
(replace if worn). Reassemble
and tighten carefully (figures
14-15).
Replace the seals of the fitting,
clean or replace the filter.
Clean the air ducts in the
conveyor. Ventilate the work
area. Reset the thermal cutout.
On lubricated and V type
models, check oil level and
quality. On V models, have the
voltage checked.
Activate the on/off switch.
Ventilate the work area. Wait a
few minutes. The compressor
will restart independently. On V,
3 HP models, reset the thermal
cutout. Remove any power cable
extensions.
Remove the plug and contact
the Service Center.
G
B

Publicidad

Tabla de contenido
loading

Tabla de contenido