2. Installation Location Selection
● The appliance should be installed indoor. It is not allowed to install the appliance outdoor or in humid
places.
● If the appliance is installed in the place vulnerable to rain, it is essential to take the necessary
water-resistant measures to prevent rain entering into the internal components, otherwise the
components may be eroded easily and cause physical danger.
● The appliance must be installed on a sufficiently strong and horizontal floor. In order to drain
condensate water from evaporate smoothly, the inclination angle to the floor should no more than
1.5°.
● Select a place where there has good ventilation and the air outlet should avoid facing the wind
direction. There should be no obstacles at the air inlet and air outlet.
● Select a place where water pipes and electric power can be easily connected.
● Select a place where water drained out of the relief valve will not splash on the wood floor or
furniture.
● Reserve space for installation and maintenance shown as Fig.4.
3. Air Duct Connection
The appliance is designed to connect duct that can provide additional practical function as
described below. For the case of the appliance connected with duct, the diameter of the duct must ≥
170 mm. The total length, typically using flexible plastic duct, should not exceed the maximum length of
6m.
Upon connect duct, portion airflow will lose, which will lead to capacity decreased in the system.
Fig.4 Recommended installation and maintenance space