Fig.6 Pipeline system connection
ATTENTION
● Do not use iron pipe to install the appliance. The water pipeline system should adopt new pipes that
can meet drinking water standards, such as CPVC/PPR pipe or PB. Please do not use smelly PVC pipe.
● Install the water pipes, connectors and other parts according to above figure. If the installation
environment is under 0℃, all pipes should be with insulation treatment.
● Please keep the condensate water outlet and safety valve outlet clean and unblocked.
●Condensing pipe should be able to drain water smoothly, condensing pipe must be installed from high
to low, without turning upward.
6. Pipeline Connection Instructions
(1) Installation requirements of water inlet pipes
Screw thread is 3/4" BSP F. The lifetime of pipes and pipe components cannot be shorter than the
lifetime of the appliance, and they should be able to withstand high temperature of 80℃, so as to avoid
damage.
(2) Installation requirements of safety valve connection pipes
Screw thread of inlet side is 3/4'' BSP M and the outlet side is 3/4'' BSP F. Make sure the water can flow
out of the safety valve and the drainage outlet should be installed straight downwards. After finishing
installation, please make sure that drainage hose connected to the safety valve's drainage outlet should
be maintain downward and stay open to the frost-free environment.
(3) The pressure ranges of the water tank is 0.15MPa~1.0MPa. If the water inlet pressure is always
lower than 0.15MPa and in order to get higher water flow to meet water consumption requirement,
you need to add a booster pump at the water inlet so as to keep the water pressure no lower than
0.15MPa; if the water inlet pressure is always higher than 0.5MPa, you need to add a reducing valve of
0.5MPa at water inlet pipe so as to make sure the safety use of the tank.