Descargar Imprimir esta página

Sime ECOMAXI VB 200 Instrucciones De Instalación Y Funcionamiento página 48

Ocultar thumbs Ver también para ECOMAXI VB 200:

Publicidad

Idiomas disponibles

Idiomas disponibles

■ Technical Parameters
Model
Operational mode
Power supply
Max. power input (under boost mode)
Max. current input (under boost mode)
Max. power input
Heating up time
Refrigerant
Declared load profile
COP
DHW
Heat pump
Mixed water at 40℃
Energy efficiency
Energy efficiency class
Annual electrical consumption
Max. outlet water temp.
Operating temp. range
Rated power input
Electric
heating
Max. outlet water temp.
Max. operating pressure for refrigerant
circuit (discharge side/suction side)
Rated capacity
Max. operating Pressure
Storage
tank
Water inlet/outlet
Solar energy inlet/outlet
Anti-electric shock class
Sound power level
(3)
Net weight(kg)
Dimensions(mm)
Note (1): Performance condition: ambient air 7°C DB/ 6°C WB, incoming/final water temperature 10°C /
52°C, according to EN 16147:2017, (EU) NO 814-2013.
Note (2): Performance condition:ambient air 14°C DB/ 13°C WB, incoming/final water temperature
10°C / 52°C, according to EN 16147:2017, (EU) NO 814-2013.
Note (3): Sound power level tested with air duct, according to EN 12102-1-2017, ISO 3744:2010.
ECOMAXI VB 200
Heat pump, Automatic and Boost mode
220-240V~ 50Hz
2400W
5:24(h:min)
R134a/600g
2.797
(1)
243.7L
(1)
117.7%
(1)
A+
(1)
870kWh
(1)
65℃ (default 52℃)
-7℃~43℃
1500W
2.4MPa/0.6MPa
1.0MPa
58dB (A)
φ662*1530
16
10.43A
900W
L
3.331
(2)
247.1L
(2)
139.6%
(2)
A+
(2)
733kWh
75℃
200L
DN20
/
Class Ι
125
(2)

Publicidad

loading

Este manual también es adecuado para:

Ecomaxi vb 300Ecomaxi vb 300 s811584381158448115845