Hardware Installation NXFM100 Wiring (continued)
Figure 1
INPUT
DC+
1
DC-
1
2
2
3
4
OUTPUT
3
DC+
4
DC-
Figure 2
INPUT
5
Line
Neutral
6
5
7
Ground
6
7
OUTPUT
8
9
8
Line
10
9
Neutral
Ground
10
Hardware Installation - Pulsers - NXFM100
• Do not attach AC power to the terminal marked "12V DC". This terminal is for DC powered pulsers only. Attaching AC power to this terminal will
destroy your Fill-Rite FMS board.
The wiring configuration for pulsers depends on whether you are using a 2 wire pulser
or a 3 wire pulser. All pulser wiring should be connected to the terminals 12, 13, and 14
as demonstrated in the graphic below.
2-Wire Pulser:
For 2 wire pulsers, it does not matter which of the two wires you attach to each terminal:
• Attach one wire to the terminal marked 'Pulse' - Terminal (13)
• Attach one wire to the terminal marked 'GND' - Terminal (12)
Fill-Rite FMS
12v+
13
Pulse
12
GND
Level
Fill-Rite FMS
fillrite.com
14
FUEL MANAGEMENT SYSTEM
DC-
DC+
23
24
23 24
PU LS ER
Pulse
Pulse
P ULS ER
12v+
INSTALLATION AND OPERATION MANUAL
DC
DC power has 8-50V DC positive and negative wires. For power input,
attach the appropriate wire to the designated terminals on the top bank
of terminals on the Fill-Rite FMS board (see Figure 1).
For power output, attach the appropriate wire to the designated
terminal on the bottom bank of terminals on the Fill-Rite FMS board
as demonstrated in Figure 1.
AC
AC power has a line, neutral, and ground wire. For power input, attach
the appropriate wires to the designated terminal on the top bank of
terminals of the Fill-Rite FMS board (see Figure 2).
For power output, attach the appropriate wires to the designated
terminal on the bottom bank on terminals of the Fill-Rite FMS board
as demonstrated in Figure 2.
Fill-Rite FMS
12v+
3-Wire Pulser:
13
Pulse
• Attach 12V power line from the pulser to the '12V+' terminal - Terminal (14)
12
GND
• Attach signal wire to the 'Pulse' terminal - Terminal (13)
Level
• Attach the ground wire to the 'GND' terminal - Terminal (12)
• For quadrature signal, use one leg of the signal only. This device is not
approved for custody transfer
Fill-Rite FMS
14
12v+
13
Pulse
12
GND
Level
P ULSE R
Pulse
Pulse
PU LS ER
12v+
Signal
GND
5

Publicidad

loading