1. GENERAL
Read carefully the instructions before installing this unit. Verify
the technical characteristics of the motor in order to assure the
compatibility with the device.
2. DESCRIPTION (diagram A)
SWITCHMATIC 1 is an electronic pressure switch with integrated
digital manometer. It manages the start and stop of a single-pha-
se pump up to 2.2kW (3 HP) (SW1-2). Cut-in and cut-out pressures
are easily adjustable through the users control panel.
Wiring is analogous to the traditional electromechanical switch.
It can operate as a differential pressure switch and as reverse pres-
sure
switch.
Unit SWITCHMATIC 2 in addition to all the features of the basic
SWITCH- MATIC includes instantaneous reading of current drawn.
This patented system controls and manages the overcurrent, dry-
run operation and fast-cycling.
Unit SWITCHMATIC 2 in addition to all the features of individual
assembly includes the option to be synchronized to another unit
SWITCHMATIC 2 managing and protecting 2 pumps operating in
cascade with alternated starting sequence. The SWITCHMATIC 3
unit is ideal for a control panel as it has a dry contact output.
3. OPERATING CHARACTERISTICS (diagram C)
• Adjustable cut-in and cut-out pressures.
• Integrated digital pressure gauge with bar and psi indication.
• Inner pressure transmitter.
• Dry-run protection:
• Through minimum adjusted height for basic
1/3.
• Through the instantaneous current consumption in case of
SW2.
• Overcurrent protection.
• Overvoltage protection.
• ART Function (Automatic Reset Test). When the device has
stopped the pump by the intervention of the dry-running
protection system, the ART tries, with scheduled basis, to re-
start the pump in order to restore the water supply. See "ART.
Automatic reset function". Must be activated in the step 6 of
the ADVANCED MENU (Ar1).
• Fast cycling: when the hydropneumatic tank has lost too much
air and, consequently, frequent start-stop cycles are produced
this alarm is activated and is delayed the start of the pump.
Activated (rc2).
• Manual start push-button (ENTER).
• 3 operation modes: differential, reverse and synchronized.
• Control panel with 3-digit display, LED indicator lights and
push-buttons.
• Volt-free contact for monitoring the alarms displayed in the
screen (only version in-out).
• Connections for a level switch, its use is optional (in-out mo-
dels only).
• Available settings:
• Stand-by mode.
• Minimum period between fast cycles.
• Start and stop delay.
4. TECHNICAL CHARACTERISTICS
• Rated motor power:
• Power supply:
• Electric outlet:
• Nominal pressure
• Frequency:
• Max. current:
• Protection degree:
• Max water Temperature:
• Max environment Temperature: 60ºC
• Cut-in range (start pressure)
• Cut-ot range (stop pressure)
• Max. differential (Pstop-Pstart)
• Minimum diff. (Pstop-Pstart)
• Factory setting (start/stop)
• Hydraulic inlet
• Net weight (without cables)
SWITCHMATIC
0,37-2,2 kW (SW1-SW2)
~1 x 110-230 V (SW1-SW2)
~1 x 48-230 Vac/Vdc (SW3)
~1 x 24 Vac/Vdc (SW3 24V)
Dry contact (SW3)
1MPa/10bar (plus:13bar)
50/60Hz
16 A, cos fi ≥ 0.6 (SW1-2-3)
10 A, cos fi ≥ 0.6 (SW3 24V)
IP55
50ºC
0,5÷7 bar (v. plus=11 bar)
1÷8 bar (v. plus=12 bar)
7,5 bar (v. plus=11,5 bar)
SW: 0,5 bar
SW2 synchro: 1 bar
3/4 bar
G1/4" Fem. - NPT 1/4" Fem.
0,3 kg
5. HYDRAULIC INSTALLATION (diagram A)
SWITCHMATIC units must be threaded to a fitting G1/4" male
at the pump´s outlet.
Before connecting the SWITCHMATIC verify that the hydraulic
system is properly installed, especially if the hydropneumatic tank
is pressurized.
6. ELECTRIC CONNECTION (diagram B)
The electric connection must be performed by qualified per-
sonal in compliance with regulation of each country. Before
doing manipulations inside the device, it must be disconnected
from the electric supply.
Wrong connection could spoil the electronic circuit.
The manufacturer declines all responsability in damages
caused by wrong connections.
When carrying out the electrical connection it is compulsory to
use a differential switch of high sensitivity: I = 30 mA (clase A o
AC). It is compulsory to use a magnetothermic switch adapted at
the motor load.
Check if power supply is between
If you have purchased the unit without cables follow
• Use cables type H07RN-F 3G1 or 3G1,5 with section enough to
the power installed.
• Do the pump connection U, V and
to the control panel (Only SW3)
• Do the power supply connection L1, N and . (SW1-2-3) or
24V + and - (SW3 24V)
• The earth conductor must be longer than the others. It will be
the first one to be mounted during the assembly and the last
one to be disconnected during the dismantling. The earth
conductors connections are compulsory!
• (Only version in-out) The device has a volt-free contact for
monitoring the alarms displayed in the screen originated by
irregularities or problems of the system. See Diagram C for
connection.
• (Only version in-out) There is a level switch input in the auxiliary
circuit. See Diagram C for connection.
7. CONTROL PANEL (diagram D)
The meanings of the different control panel elements are sum-
marized on the following tables, where:
• O means lit LED light.
• ( ( O ) ) means slow-flashing.
• (((O))) means fast-flashing.
DISPLAY
OPERATION
Is showed on screen instantaneous pressure or
MODE
instantaneous current consumption
Is displayed on screen the adjusted start pressure
blinking.
ADJUSTMENT
Is displayed on screen the adjusted stop pressure
MODE
blinking.
Is displayed the adjusted rated current blinking
(only SW2).
ALARM MODE
Is displayed the alarm code
STAND-BY MODE
Are displayed 3 flashing dots
BASIC CONFIGU-
Is displayed the sequence of basic configuration
RATION MODE
parameters
ADVANCED
Is displayed the sequence of advanced configura-
CONFIGURATION
tion parameters
MODE
LEDS
STATE
O
It indicates the instantaneous pressure in bar
bar
It indicates the instantaneous pressure in bar
( ( O ) )
+
O
It indicates the instantaneous pressure in psi
psi
It indicates the instantaneous pressure in psi
( ( O ) )
+
It indicates the instantaneous current con-
O
A
sumption in Ampere units
(only SW2)
( ( O ) )
Pump ON
O
Is displayed the start pressure
START
( ( O ) )
Adjusting start pressure
O
Is displayed the stop pressure
STOP
( ( O ) )
Adjusting stop pressure
2
115-230V (SW1-2).
diagram B:
(SW1-2) or C1, C2 and
ACTION
MEANING
pump operating (only SW1/SW3)
pump operating (only SW1/SW3)