P-BUT-
TOUCH
TON
From state ON: unit OFF.
From state OFF: the pump starts and
click!
keeps operating until reaching Pstop.
From any configuration MENU: the
parameter value is accepted.
From state ON: unit OFF.
HOLD
From state OFF: the pump starts and
DOWN
keeps operating until the push-button
is released.
Pstart is displayed on the screen for 3
click!
seconds.
3"
Pstart adjustment mode.
Pstop is displayed on the screen for 3
click!
seconds.
3"
Pstop adjustment mode.
Is displayed on the screen instantaneous
current consumption.
click!
If it is already displayed then we switch
to instantaneous pressure view.
3"
Rated current adjustment.
8. STARTUP (diagram C)
Before starting the device please read the previous sections,
especially "Hydraulic Installation" and "Electrical connec-
tion".
Follow next steps:
1. Only for type SW2 set the pump rated current intensity value.
- Press
during 3 seconds.
- The current intensity value is displayed on screen, LED A
lights up and display is flashing.
- By mean of
and
in the characteristics plate of the motor. See Note 1.
- Press
for validation.
2. Start the device by pressing
3. Set the cut-in (start) pressure:
- Press
during 3 seconds.
- The start pressure value is displayed on screen, LED START
lights up and display is flashing.
- By mean of
and
to 7 bar (+ version=11 bar).
- Press
for validation.
4. Set the cut-out (stop) pressure:
- Press
during 3 seconds.
- The stop pressure value is displayed on screen, LED STOP
lights up and display is flashing.
- By mean of
and
8 bar (+ version=12 bar).
- Press
for validation.
5. The unit is ready to operate but more optional adjustments can
be set through basic and advanced MENUS. See the next chapter.
Remark 1: it is important to introduce exactly the rated
current specified on the nameplate of the pump.
ACTION
is adjusted the rated current reflected
.
is adjusted the start pressure from 0,5
is adjusted the stop pressure from 1 to
9. BASIC MENU
+
- Press simultaneously
- By mean of
or
- Press
for validation.
- The parameters sequence is:
it
TYPE
SYSTEM REACTION
We can select the pressure units
1
BAR
P
displayed beetween bar and psi.
Fast-cycling alarm:
- rc0: alarm unabled.
- rc1: activated, when hammering is
detected it is delayed the start
2
rc0
rc2
in order to protect the pump.
- rc2: alarm is activated and the
pump is stopped upon detec-
tion.
Only if fast-cycling alarm has been
activated in the previous step
(rc1&rc2). It can be choosed the
2.1 r.01 r.99
maximum time period between 3
consecutive starts that will be con-
sidered fast cycling (between 1 sec.
and 99 sec.)
Stand-by mode activated (Sb1), for
3
Sb0 Sb1
low power consumption, or unabled
(Sb0).
3
(diagram C)
+
during 5 seconds.
the values can be changed.
FACTORY
SETTING
bar
rc2
3 seconds
Sb0