Menu structure
2
Set torque value
•
Enter torque value
Set unit of measurement
•
N·m
•
ft·lb
•
in·lb
Set function mode
•
On (cut-out),
•
OFF (indicating), no symbol in the display
Set bolting tolerance
•
On (with bolting tolerance)
– Enter negative tolerance
– Enter positive tolerance
• OFF (without bolting tolerance), no symbol in the display
Save values
•
On (bolting data are saved)
– Enter bolting application number
In delivery condition, the bolting application number is "0000".
• OFF (bolting data are not saved), no symbol in the display
Extension correction
• On (with extension setting)
– Enter extension
• OFF (standard extension), no symbol in the display
Automatic subsequent taring
• On (automatic subsequent taring switched on)
• OFF (no automatic subsequent taring),