3.6 Rapid intervention digital inputs (Connector CN4)
CN4-1
Wire 35
CN4-5
Wire 28
3.7 Analog inputs (connector CN1 - CN4 - CN5)
The maximum voltage applicable to an analog input on RI200 is 14V (adjustment range: 0-14V).
A different range for the voltage signal (e.g. adjustment range: 0-10V or 0-5V) can be set by programming analog inputs on
RC300.
CN4-6
Wire 29
CN4-2
Wire 34
CN4-7
Wire 30
CN4-3
Wire 33
CN1-7
Wire 21
CN1-1
Wire 25
CN5-2
Wire 26
CN5-1
Wire 27
SAVING PARAMETERS: command signal for instantly saving welding parameters.
0V = saving parameters
24V = no active command
EMERGENCY: command signal for total shut-down of the welding process. For connection to
the system's safety devices.
0V = system in alarm status
24V = system operating normally
ANALOG INPUT 1 : positive input (+)
ANALOG INPUT 1 : negative input (-)
The parameter managed by this analog input can be selected and programmed by RC300.
Default: welding current.
0V = minimum of selected parameter
14V = maximum of selected parameter
ANALOG INPUT 2 : positive input (+)
ANALOG INPUT 2 : negative input (-)
The parameter managed by this analog input can be selected and programmed by RC300.
Default: welding voltage.
0V = minimum of selected parameter
14V = maximum of selected parameter
ANALOG INPUT 3 : positive input (+)
ANALOG INPUT 3 : negative input (-)
The parameter managed by this analog input can be selected and programmed by RC300.
Default: not programmed.
0V = minimum of selected parameter
14V = maximum of selected parameter
ANALOG INPUT 4 : positive input (+)
ANALOG INPUT 4 : negative input (-)
The parameter managed by this analog input can be selected and programmed by RC300.
Default: not programmed.
0V = minimum of selected parameter
14V = maximum of selected parameter
CN9-6/7/13/14
CN4-1 (35) SAVING PARAMETERS
CN4-5 (28) EMERGENCY ALARM
29