5 CONNECTORS
5.1 Connector CN1 (12-pole)
CN1-1
Wire 25
CN1-6
Wire 24
CN1-7
Wire 21
CN1-11 Wire 22
CN1-12 Wire 23
CN1-3
CN1-9
CN1-4
5.2 Connector CN2 (4-pole)
CN2-1
Wire 20
CN2-2
Yellow green wire Ground (PE)
CN2-3
Wire 19
CN2-4
Wire 18
5.3 Connector CN3 (16-pole)
CN3-1
Wire 16
CN3-2
Wire 15
CN3-3
Wire 14
CN3-4
Wire 13
CN3-5
Wire 12
CN3-6
Wire 11
CN3-7
Wire 10
CN3-8
Wire 9
CN3-9
Wire 1
CN3-10 Wire 2
CN3-11 Wire 3
CN3-12 Wire 4
CN3-13 Wire 5
CN3-14 Wire 6
CN3-15 Wire 7
CN3-16 Wire 8
ANALOG input 3 (-)
LINE B (RS485)
ANALOG input 3 (+)
LINE A (RS485)
GND (RS485)
RS232 (RX)
RS232 (TX)
GND (RS232)
+24V
Ground
Ground
START ARC input
0V = arc OFF
24V = arc ON
Input for GLUED WIRE TEST
AND PIECE SEARCH
0V = test inactive
24V = test active
WIRE BACK input:
0V = wire back inactive
24V = wire back active
GAS TEST input
0V = test inactive
24V = test active
AIR TEST input
0V = no air flow
24V = air flow
WIRE EXTENSION input:
0V = wire not extended
24V = wire extended
ALARMS RESET input
0V = no reset operation
24V = alarms reset
SYNERGY/MEMORY input
0 = synergetic curve retrieval
enabled
1 = retrieval of stored welding
spots enabled
Coding input
Coding input
Coding input
Coding input
Coding input
Coding input
Coding input
PROCESS input
0 = selection of MIG Short Spray
Arc process
1 = selection of Pulsed process.
5.4 Connector CN4 (8-pole)
CN4-1
Wire 35
CN4-2
Wire 34
CN4-3
Wire 33
CN4-5
Wire 28
CN4-6
Wire 29
CN4-7
Wire 30
5.5 Connector CN5 (2-pole)
CN5-1
Wire 27
CN5-2
Wire 26
5.6 Connector CN7 (6-pole)
CN7-1
Wire 49
CN7-2
Wire 50
CN7-3
Wire 51
CN7-4
Wire 48
CN7-6
Wire 46
5.7 Connector CN7 (10-pole)
CN8-1
Wire 41
CN8-2
Wire 42
CN8-3
Wire 43
CN8-4
Wire 44
CN8-5
Wire 45
CN8-6
Wire 40
CN8-7
Wire 39
CN8-8
Wire 38
CN8-9
Wire 37
CN8-10 Wire 36
5.8 Connector CN9 (14-pole)
CN9-1
CAN-H
CN9-2
Ground
CN9-4
Ground
CN9-5
Ground
CN9-6
+24V
CN9-7
+24V
CN9-8
CAN-L
CN9-11 Ground
CN9-12 Ground
CN9-13 +24V
CN9-14 +24V
PARAMETER SAVING input
0V = saving parameters
24V = no active command
ANALOG input 1 (-)
ANALOG input 2 (-)
EMERGENCY ALARM input
0V = system in alarm status
24V = system operating normal-
ly
ANALOG input 1 (+)
ANALOG input 2 (+)
ANALOG input 4 (-)
ANALOG input 4 (+)
"WELDING TOOL READY" out-
put
0V = system in alarm status
24V = system ready for use
GAS PRESENCE output
0V = "no gas" alarm
24V = gas present
WATER PRESENCE output
0V = water present
24V = "no water" alarm
SAFETY LIMITS output
0V = safety limits alarm active
24V = no active alarm
PIECE PRESENCE output
0V = piece not touched
24V = piece touched
ARC ON output
0V = arc OFF
24V = arc ON
ANALOG output 1 (+)
ANALOG output 2 (+)
ANALOG output 3 (+)
ANALOG output 4 (+)
GLUED WIRE PRESENCE output
0V = wire not glued
24V = wire glued
ANALOG output 1 (-)
ANALOG output 2 (-)
ANALOG output 3 (-)
ANALOG output 4 (-)