Descargar Imprimir esta página

Selco 1000 Serie Instrucciones De Uso página 31

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3.9 Analog outputs (connector CN8)
Analog outputs can supply a voltage value in the range 0 to 10V and in proportion to a quantity measured and preset on RC300.
CN8-2
Wire 42
CN8-7
Wire 39
CN8-3
Wire 43
CN8-8
Wire 38
CN8-4
Wire 44
CN8-9
Wire 37
CN8-5
Wire 45
CN8-10
Wire 36
ANALOG OUTPUT 1 : positive output (+)
ANALOG OUTPUT 1 : negative output (-)
Default: the parameter managed by this analog output is welding current.
0V = minimum of selected parameter
10V = maximum of selected parameter
ANALOG OUTPUT 2 : positive output (+)
ANALOG OUTPUT 2 : negative output (-)
Default: the parameter managed by this analog output is welding voltage.
0V = minimum of selected parameter
10V = maximum of selected parameter
ANALOG OUTPUT 3 : positive output (+)
ANALOG OUTPUT 3 : negative output (-)
The parameter managed by this analog input can be selected and programmed by RC300.
Default: not programmed.
0V = minimum of selected parameter
10V = maximum of selected parameter
ANALOG OUTPUT 4 : positive output (+)
ANALOG OUTPUT 4 : negative output (-)
The parameter managed by this analog input can be selected and programmed by RC300.
Default: not programmed.
0V = minimum of selected parameter
10V = maximum of selected parameter
31