oPerATIoN
Settings
Multifunction assembly (MFG)
3-way diverter valve: The multifunction assembly switches be-
tween heating circuit and DHW heating.
Safety valve: When the pressure is high, the safety valve opens to
relieve the pressure in the system.
Air vent valve: Components are vented through air vent valves,
e.g. pipes or indirect coil.
Emergency/booster heater: in standard mode, the emergency/
booster heater can support the heat pump in mono energetic
mode below the dual mode point. Depending on the setting and
connected heat pump, the emergency/booster heater can also be
used to back up DHW heating or in pasteurisation mode. In the
event of a heat pump malfunction, the emergency/booster heater
can temporarily ensure DHW heating and the heating of rooms.
5.
Settings
Material losses
!
The system's active frost protection is not guaranteed if
the power supply is interrupted.
f Never interrupt the power supply even outside the
heating season.
Note
The heat pump manager has an automatic summer/win-
ter changeover so you can leave the system switched on
in summer.
The system is controlled by means of the integral heat pump
manager. Please observe the heat pump manager operating and
installation instructions.
MENU
www.stiebel-eltron.com
OK
6.
Cleaning, care and maintenance
f Have the electrical safety of the appliance and the function
of the safety assembly regularly checked by a qualified
contractor.
f Have the sacrificial anode checked by a qualified contractor
after the first two years of use. The qualified contractor will
then determine the intervals at which the sacrificial anode
should be checked.
f Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the unit.
7.
Troubleshooting
Problem
Cause
The water does not heat
There is no power.
up. The heating does not
work.
Observe the information about troubleshooting in other applicable
documents (see chapter "Other applicable documents").
If you cannot remedy the fault, contact your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-000000).
HSBC 180 Plus | HSBC 180 S Plus |
remedy
Check the fuses / MCBs in
your fuse box / distribu-
tion board.
No.: 000000-0000-000000
Made in Germany
31