Installation
Material losses
!
Always carry the appliance by the carrying straps.
Never transport the appliance using a hoist.
During transportation, never subject the pipe connectors
to any strain.
Protect the appliance against heavy impact during trans-
port.
f Lift the appliance off the pallet by the carrying straps.
f After transportation, tuck the lower carrying straps under the
appliance. You can also cut off the upper and lower carrying
straps.
11. Installation
11.1 Positioning the appliance
f When positioning the appliance, observe minimum clearanc-
es (see chapter "Preparations / Installation site").
f Use the adjustable feet to compensate for any unevenness in
the floor.
11.2 Removing/fitting the front casing
Removing the front casing
Material losses
!
If you remove the front panel from the appliance at an
angle or unevenly, you may damage it.
f Remove the front panel from the appliance by pull-
ing it evenly and in a straight line.
1
2
1 Upper front panel
2 Lower front panel
f Remove the screws on the left and right of the upper front
panel.
f Carefully pull the upper front panel forwards to remove it
from appliance and store it securely so that it cannot tip over,
without putting strain on the cable connections.
34
| HSBC 180 Plus | HSBC 180 S Plus
f To be able to store the upper front panel at a distance from
the appliance, loosen the cable tie, unplug the connector
from the electronic assembly for operation (AA01-X1.18) and
the earth (XE05) at the heat pump manager and store the
front panel securely so that it cannot tip over.
f Remove the screws on the left and right of the lower front
panel.
f Pull the lower front panel forwards and store it securely so
that it cannot tip over.
Fitting the front casing
Fit the front casing in reverse order. Take care to position the
connection lines correctly and not to pinch any cables.
11.3 Heating water connection and safety valve
11.3.1 Safety instructions
Material losses
!
The heating system to which the appliance is connected
must be installed by a qualified contractor in accord-
ance with the water installation drawings in the technical
guides.
Material losses
!
When fitting additional shut-off valves, install a further
safety valve in an accessible location on the heat gen-
erator itself or in the flow line in close proximity to the
heat generator.
There must not be a shut-off valve between the heat gen-
erator and the safety valve.
Note
The use of non-return valves in the charging circuits be-
tween the heat generator and the buffer or DHW cylin-
der can impair the function of the integral multifunction
assembly (MFG) and lead to faults in the heating system.
f Only use our standard hydraulic solutions for the
installation of the appliances.
XE05