Descargar Imprimir esta página

Stiebel Eltron HSBC 180 Plus Operación E Instalación página 50

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 148
INSTALLATIoN
Specification
16.3 Energy consumption data
Product datasheet: DHW cylinder to Regulation (EU) No 812/2013 (S.I. 2019 No. 539 / Programme 2)
Manufacturer
Supplier's model identifier
Energy efficiency class
Standby losses S
Cylinder capacity V
16.4 Data table
Hydraulic data
Nominal capacity, DHW cylinder
Nominal capacity, buffer cylinder
Surface, indirect coil
Content, indirect coil
External available pressure differential, circulation pump / heat pump at 1.0 m³/h
External available pressure differential, circulation pump / heat pump at 1.5 m³/h
External available pressure differential, circulation pump / heat pump at 2.0 m³/h
External available pressure differential, circulation pump / heating circuit 1 at 1.0 m³/h
External available pressure differential, circulation pump / heating circuit 1 at 1.5 m³/h
External available pressure differential, circulation pump / heating circuit 1 at 2.0 m³/h
Application limits
Max. permissible pressure, DHW cylinder
Test pressure, DHW cylinder
Max. throughput
Max. permissible pressure, buffer cylinder
Test pressure, buffer cylinder
Max. permissible temperature
Max. permissible temperature, primary side
Heating water quality requirements
Water hardness
pH value (with aluminium compounds)
pH value (without aluminium compounds)
Conductivity (softening)
Conductivity (desalinating)
Chloride
Oxygen 8-12 weeks after filling (softening)
Oxygen 8-12 weeks after filling (desalinating)
Power consumption
Power consumption, emergency/booster heater
Max. power consumption, charging pump
Max. power consumption, circulation pump, heating side
Energy data
Standby energy consumption/24 h at 65 °C
Energy efficiency class
Electrical details
Rated control voltage
Control phases
Control circuit fuse
Rated voltage, emergency/booster heater
Phases, emergency/booster heater
Emergency/booster heater fuse
Frequency
Versions
IP-Rating
50
| HSBC 180 Plus | HSBC 180 S Plus
HSBC 180 plus
STIEBEL ELTRON
HSBC 180 plus
W
l
hPa
hPa
hPa
hPa
hPa
hPa
MPa
MPa
l/min
MPa
MPa
°dH
μS/cm
μS/cm
mg/l
mg/l
mg/l
kW
kWh
202927
B
53.9
195
HSBC 180 Plus
202927
l
178
l
80
1.59
l
10
690
461
219
728
555
401
1.00
1.50
25
0.30
0.45
°C
95
°C
75
≤3
8.0-8.5
8.0–10,0
< 1000
20-100
< 30
<0.02
< 0.1
8.80
W
60
W
60
1.29
B
V
230
1/N/PE
A
1 x B 16
V
400
3/N/PE
A
3 x B 16
Hz
50
IP20
www.stiebel-eltron.com
HSBC 180 S Plus
203082
STIEBEL ELTRON
HSBC 180 S Plus
B
53.9
195
HSBC 180 S Plus
203082
178
80
1.59
10
690
461
219
728
555
401
1.00
1.50
25
0.30
0.45
95
75
≤3
8.0-8.5
8.0–10.0
< 1000
20-100
< 30
<0.02
< 0.1
5.90
60
60
1.29
B
230
1/N/PE
1 x B 16
230
2/N/PE
2 x B 16
50
IP20

Publicidad

loading

Este manual también es adecuado para:

Hsbc 180 s plus