3.2.7.1 Technical characteristics
- Sensor technology: Inductive, with temperature compensation
- Measurement range: 0 to 10g/l
- Resolution: 0,1g/l
- Supply: 12V DC
3.2.7.2 Installation
Please, follow the installation instructions from the specific manual
included in this kit. It contains detailed instructions about hydraulic
installation and electric connection with the chlorinator.
3.2.7.3 Operation and adjustment
Once the conductivity sensor is connected, the chlorinator will detect it
automatically.
The main screen will show the measure, and also any warning related with the lack
or too much salt conditions:
PRO units
Lack of salt: Measure < 4g/l
Too much salt: Measure > 8g/l
3.2.7.4 Calibration and maintenance
The conductivity sensor comes already calibrated, however, it is possible to Access
to a calibration menu in case that a measurement fine tuning would be required.
Use an external measure system and then set the value in the salt adjust menu.
Press OK to confirm the new calibration.
This sensor does not require any special maintenance. However, if an incorrect
value is observed, an visual inspection of the measure head is recommended, in
order to detect any strange body which could be interfering with the correct
operation.
50 / 66