4.2.1- Warning messages
Message:
"LACK OF SALT"
"EXCESS SALT"
"CLEANING"
"TEMPERATURE".
4.2.2- Alarm Messages
In the following cases, the chlorinator shuts down and the alarm and
acoustic alarm LED is activated (automatic reset once the fault is solved):
"NO
WATER
FLOW"
Manual PRO200-IP65 v1.0
Causes:
Lack of salt in the water.
Incrustations or objects in
the electrolysis cell causing
excess current.
The electrolysis cell is worn.
Excess salt in the water.
Incrustations or objects in
the electrolysis cell causing
excess current.
The chlorinator is in the
self-cleaning process. The
process lasts 5 minutes
The ambient temperature is
>40º
The
radiator
fins
obstructed or are not in a
vertical position.
Excess
gas
in
electrolysis cell. It may
have occurred because the
pump has shutdown. The
gas is hydrogen gas which
is highly flammable.
The flow switch is wrongly
connected or damaged
No water flow
Action required:
Add salt to the swimming pool.
Clean the cell.
Replace the electrolysis cell with
a new one.
No action required if excess is
not very significant.
Clean the cell.
None.
Try and place the equipment in
another position where it is not
over 40º or perform forced
ventilation.
equipment to rest for a few
minutes.
Consult section number
4. Installation
are
Place the equipment so that air
is circulated for correct cooling.
the
The piping should be drained to
eliminate gas or accumulated
water. Check the pump.
Check that the flow switch is
correctly connected and works
properly.
Check the hydraulic installation.