Table 2: Operating malfunctions
Problem
Gas odour
The pilot flame does not ignite
The pilot flame does not remain
on
GAS CONNECTION
All the gas connection, transformation and pressure control operations must be performed by
authorised personnel who must have specific technical skills and special abilities in the spe-
cific sector. This also applies for all extraordinary maintenance operations such as lubrication
and/or faucet replacement and thermocouple or burner replacement.
Equip the appliance gas supply tube with a faucet to be able to cut of gas supply in the event
of need.
The faucet (not supplied with the appliance) must be installed in a visible and accessible posi-
tion in order to easily identify its operating status (open or closed).
GAS SUPPLY TRANSFORMATION
The appliance is marketed with indications of the gas mains used by the manufacturer for
inspections.
If the gas mains do not correspond to the one used for inspection, before connecting the
gas mains, the installation technician must "transform" the appliance and indicate the
type of gas in use on the plate.
Important
After "transforming" the appliance to the gas mains in use, make sure there are no gas
leaks or operating defects, test the appliance and indicate the type of gas in use on the
identification plate.
To "transform" and adapt the appliance to the gas mains in use, close the gas supply
faucet and perform the listed operations.
– Burner nozzle replacement.
– Heat power adjustment to minimum
Causes
Temporary leak when flame is
extinguished.
The piezoelectric switch does
not work
The thermocouple is not
sufficiently heated
- 13 -
CREPE MACHINE
(GAS POWERED)
Solutions
Close the supply faucet and
ventilate the room
Check piezoelectric switch
efficiency.
Manually ignite the flame
Contact your dealer or
authorised service centre.
Insist with the ignition operation
longer
English language
GB