6 - Seal the adjustment screw with paint and repeat the operation on the other burner (if
installed).
7 - Reassemble the burner knob and the other burner knob (if installed).
LIQUID PROPANE GAS powered appliance (LPG)
1 - Remove the knob.
2 - Fully tighten the minimum adjustment screw (D).
3 - Pull out the knob and tighten the second burner screw (if installed).
4 - Turn on the appliance and make sure the flame is stable.
5 - Turn off the appliance. Seal the adjustment screw with paint and repeat the operation
on the other burner (if installed).
6 - Reassemble the burner knob and the other burner knob (if installed).
GAS PRESSURE CONTROL
Proceed as indicated.
1 - Close the gas supply faucet.
2 - Loosen the pressure fitting screw (E).
3 - Connect the pressure gauge to the
pressure fitting.
4 - Open the gas supply faucet.
5 - Turn on the burner, rotate the knob to
the maximum power position.
6 - Make sure the pressure indicated on
the gauge corresponds to the one on
the appliance plate.
7 - Turn off the burner, close the gas sup-
ply faucet and disconnect the pressure gauge.
EXTRAORDINARY MAINTENANCE
– All extraordinary maintenance such as broken or worn component replacement must be
performed by authorised personnel with specific technical skills and special abilities in
the specific sector.
– After maintenance (routine and extraordinary), always make sure that operations were
correctly performed before running the appliance.
- 15 -
CREPE MACHINE
(GAS POWERED)
E
English language
GB