Burner nozzle replacement
1 - Remove the cook plate.
2 - Unscrew the nozzle (A) and replace it
with the one suited for the gas used.
GB
Table 3: nozzle dimensions
Supply gas type
G20 (20mbar)
G25 (25mbar)
G30 (29mbar)
G30(50mbar)
Heat power adjustment to minimum
METHANE GAS powered appliance
1 - Turn on the appliance and run it at
maximum power for about 10 minutes.
2 - Rotate the burner control knob to the
minimum power position and pull it out.
3 - Turn the minimum adjustment screw
(D) clockwise or counter-clockwise to
achieve a stable flame.
4 - Rotate the burner control knob to turn it
off.
5 - Repeat minimum adjustment if the ap-
pliance is equipped with another burner.
CR400G1
Burner nozzle diameter
1 x 1,45 mm
1 x 1,50 mm
1 x 0,93 mm
1 x 0,85 mm
- 14 -
CREPE MACHINE
(GAS POWERED)
A
CR400G2
Burner nozzle diameter
2 x 1,45 mm
2 x 1,50 mm
2 x 0,93 mm
2 x 0,85 mm
D
English language