Accuracy (cont'd)
DC Current
Range
400.0 A
± (1.0% + 0.3 A)
1000 A
± (1.9% + 7 A)
Position error: 1%
Remanence Error: 1% of current crest
DC Voltage
Range
400.0 V
± (0.7% + 0.2 V)
1000 V
± (0.7% + 2 V)
Resistance
Range
400.0 Ω
1000 V overload protection
Frequency (Current Mode)
Range
0.020 to 0.400 kHz ± (0.1% + 0.002 kHz)
Peak Hold
Accuracy of held value is ± (3% + 20 digits).
Accuracy is unspecified above 750 V peak and above 800 A peak.
Min Max
Add ±15 digits to AC/DC current specification.
The meter switches to the 1000 V or 1000 A range when Peak Hold or MIN MAX is activated.
14
Accuracy
Accuracy
± (1.0% + 0.3 Ω)
Accuracy
Input Impedance
1 MΩ
Accuracy
Minimum Input
3 A RMS