MAGNETIC SmartKey™
The use of a Magnetic SmartKey (39) is required to operate this machine. Pressing the power switch without a key in place on the SmartKey
Reader (22) will cause the machine to momentarily turn on and display No Key Indicator (C21) before turning off.
There are two different Magnetic SmartKeys (39).
1. The "User" (blue) key allows a basic level of access to the information menu (press Information Switch (B)).
2. The "Supervisor" (yellow) key allows an additional level of access to see Options Menu.
FIGURE 1-1
PREPARE THE MACHINE FOR USE
LEAD-ACID BATTERIES
If your machine shipped with batteries installed do the following:
Check that the batteries are connected to the machine.
Turn ON the Power Switch (H) and check the Battery Indicator (C3). If the gauge is completely filled the batteries are ready for use. If the
gauge is less than full the batteries should be charged before use. See "Charging The Batteries" section.
IMPORTANT!: IF YOUR MACHINE HAS AN ONBOARD BATTERY CHARGER REFER TO THE OEM PRODUCT MANUAL FOR
INSTRUCTIONS REGARDING SETTING THE CHARGER FOR BATTERY TYPE.
If your machine shipped without batteries installed do the following:
Consult your Authorized Advance dealer for recommended batteries.
Install the batteries by following the instructions below.
IMPORTANT!: IF YOUR MACHINE HAS AN ONBOARD BATTERY CHARGER REFER TO THE OEM PRODUCT MANUAL FOR
INSTRUCTIONS REGARDING SETTING THE CHARGER FOR BATTERY TYPE.
LEAD-ACID BATTERY INSTALLATION
WARNING!
Use extreme caution when working with batteries. Sulfuric acid in batteries can cause severe injury if allowed to contact
the skin or eyes. Explosive hydrogen gas is vented from the batteries through openings in the battery caps. This gas
can be ignited by any electrical arc, spark or flame. Do not install any lead-acid battery in a sealed container or enclosure.
Hydrogen gas from overcharging must be allowed to escape.
When Servicing Batteries...
Remove all jewelry
Do not smoke
Wear safety glasses, rubber gloves and a rubber apron
Work in a well-ventilated area
Do not allow tools to touch more than one battery terminal at a time
ALWAYS disconnect the negative (ground) cable first when replacing batteries to prevent sparks.
ALWAYS connect the negative cable last when installing batteries.