7)
OUTPUT CT Contacts
Incorporates three output contacts. Each contact has two terminals (A
and B) that are configurable using internal DIPswitches as dry contacts
or referenced to ground. To configure see figure 7.
The functionality and de-energized state (NC/NO) are configured
through the Call Point software. They may be configured as general
purpose contacts or in the evacuation system as fault notification
contacts, Emergency Mode indicator activated...
To connect as dry contacts follow figure 8. If contacts referenced to
ground are desired, follow figure 9.
SW2. UNION BETWEEN THE NEGATIVE SIDE
OF THE POWER SUPPLY AND THE CHASSIS
DIPSWITCH 1  ON*
* JOINED
DIPSWITCH 2  ON*
DIPSWITCH 1  OFF
SEPARATED
DIPSWICTH 2  OFF
* FACTORY SETTINGS
SW1. CONFIGURATION OF THE OUTPUT CONTACTS
DIPSWITCH
NUMBER
OUTPUT
CONTACT 1
OUTPUT
CONTACT 2
OUTPUT
CONTACT 3
COMPACT version 5.0.002
COMPACT
Figure 7
A/B DRY
CONTACT (*)
1
OFF
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
OFF
9
OFF
* FACTORY SETTINGS
CONTACT B
REFERENCED TO
GROUND
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
R +D Department
Modular audio matrix
with IP connection
Figure 8
CONNECTION OF THE OUTPUT CONTACTS.
AS DRY CONTACTS
Figure 9
CONNECTION OF THE OUTPUT CONTACTS.
AS CONTACTS REFERENCED TO GROUND
Figure 10
PRIMARY
POWER
Figure 11
SECONDARY
POWER
EXTERNAL
UNIT
EXTERNAL
UNIT
6