Descargar Imprimir esta página

BIANCHI VENDING BVM 952 Manual De Instalación Y Mantenimiento página 14

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
ENGLISH
INSTANT DRINKS
This process is activated when the cup and spoon dispensing processes have
been completed.
According to the type drink requested and to the distributor model, several
of the various processes described here below can be activated.
– If present, the whipper motor is activated (Fig.2.8)
-
The electro valve fixed on the soup boiler (Fig.2.9) or on the coffee boiler
(Fig.2.10). it is activated to introduce into the mixer the programmed
water quantity.
-
The Instant boiler is installed on the instant version and on the Double
Boiler Espresso version.
-
The instant product geared motor activates the helicoidal screw conveyor
so as to dispense the quantity of product programmed into the mixer (in
some versions several products can be processed in the same mixer such
as milk and chocolate) (Fig.2.11)
-
Once the preset water and powder quantity has been preset has been
supplied, the mixer is disabled after a time (T) set during the program-
ming.
3.0 MOVING AN AUTOMATIC VENDING MACHINE
3.1 Moving and transport (Fig.3.1)
The transport of the distributor must be effected by competent personnel.
The distributor is delivered on a pallet; for the shifting use a trolley and move
it slowly in order to avoid capsizing or dangerous movements.
Avoid :
– lifting the distributor with ropes or presses
– dragging the distributor
– upset or lay down the distributor during transport
– give jolts to the distributor
Avoid as the distributor:
– bumping it
– overloading it with other packages
– exposing it to rain, to cold or sources of heat
– keeping it in damp places
The construction company is not liable for any damage which may be caused
for the partial or complete non-observance of the warning notices indicated
above.
3.2 Stocking
For eventual stocking, avoid laying several machines over each other, main-
tain it in vertical position, in dry places with temperatures not inferior to
1°C (Fig.3.2).
3.3 Packing
The distributor is protected with polystyrene angles and by a transparent
film in polypropylene (Fig.3.2).
The automatic distributor will be delivered packed, assuring both a mecha-
nical protection and protection against damages from the external envi-
ronment.
On the package labels are applied indicating:
 maneouver with care
 don't turn upside-down
 protect from the rain
 don't superimpose
 protect from sources of heat
 not resistant against bumps
 type of distributor and serial number.
3.4 Reception
Upon reception of the automatic distributor you need to check that the same
has not suffered damages during the transport.
If damages of any nature are noticed place a claim with the forwarder im-
mediately.
At the end of the transport the packing must result without damages
which means it must not :
– present dents, signs of bumps, deformations or damages of the external
packaging
– present wet zones or signs that could lead to suppose that the packing
has been exposed to rain, cold or heat.
– present signs of tampering
3.5 Unpacking
-
Free the distributor from the packaging , cutting the protective film in
which it is wrapped, along one of the protection angles (Fig.3.3).
-
Remove the distributor from transport pallet, unscrewing the screws (A)
that block the fixing cross staff heads to the pallet (Fig.3.4).
– Release the pallet and insert the 4 feet into the threaded slots (fig. 3.5)
freed of the screws (A)
– remove the key from the drink dispensing chamber (Fig.3.6)
Open the door of the distributor and remove the adhesive tape from the
components listed here below:
 cup turret (example in Fig.3.7)
 coin box
 sugar container
 weight on the spoon dispenser column
 coin mechanism cover / Master board
 product containers
 water bin float mechanism
 bottom skirting-board
 water bin
 remove the polystyrene that that blocks the product containers
(Fig.3.8)
The packing material must not be left accessible to others, as it is a
potential environmental pollution sources. For the disposal contact
qualified companies authorized.
4.0
INSTALLATION
4.1 Positioning
– If positioned near to a wall, there must be a minimum distance from the
wall of at least 5 cm. (Fig.4.1) so as to allow a regular ventilation. In no
case cover the distributor with cloths or similar.
– Position the distributor, checking the leveling by means of the adjustable
feet already assembled on the machines (Fig.4.2). make sure that the
distributor doesn't have an inclination of more than 2 degrees.
WARNING! Do not position the device near inflammable objects, keep
a minimum safety distance of 30 cm.
Bianchi Vending Group spa declines all responsibility for inconveniences
due to the non observance of the above mentioned installation norms.
If the installation is made in safety evacuation corridors make sure that
with the distributor door open there is anyhow sufficient space to pass by
(Fig.4.1).
So as to avoid that the floor gets dirty, due to accidental spilling of the pro-
ducts, use, if necessary, under the distributor, a protection sufficiently wide
to cover the distributors' operating space.
4.2 Connection to the main water supply
Before proceeding with the connection of the distributor to the water main
supply verify the following water characteristics:
– that it is drinkable (eventually through an laboratory's analysis certifica-
tion)
– it has a pressure comprised between 0.5 and 6.5 (bar) ( if this should
not be the case, use a pump or a water pressure, reducer according to
the case).
– install, if not present, a tap in an accessible position to isolate the machine
from the water mains should it be found to be necessary (Fig.4.3).
– before making water connections, make some water flow out of the tap
so as to eliminate possible traces of impurities and dirt (Fig.4.4)
– connect the cock to the distributor, using a pipe in nylon material suitable
for food products and suitable for the mains pressure. In the event of the
use of a flexible pipe it is necessary to fit the reinforcement bush supplied
inside (Fig. 4.5).
– the foreseen connection is a 3/ 8 gas (Fig.4.6).
4.3 Main Power supply connection
The distributor is predisposed to function with mono-phase 230 Volt tension
and is protected with 12,5A and 20A fuses. (10A and 20A for the single boiler
and instant versions and 15A and 20A for the instant hot/cold version).
We suggest to check that:
– the tension of net of 230 V doesn't have a difference of more than ± 6%
– The power supply output is able to bear the power load of the machine.
– use a system of diversified protection
– position the machine in such a way as to ensure that the plug remains
accessible
The machine must be connected to earth in observance with the current
safety norms.
For this reason, verify the plant's earth wire connection to ascertain that it
is efficient and it answers national and European safety electric standards.
If necessary require the intervention qualified personnel for the verification
of the plant.
– The distributor is equipped
3x1,5mm², with SCHUKO plug (Fig.4.7).
– The sockets that are not compatible with that of the machine must be
replaced. (Fig.4.8).
– The use of extension, adapters and/ or multiple plugs is forbidden.
– In some models, specific plugs are assembled for the destination place.
Bianchi Vending Group spa declines all responsibility for damages deriving
for the complete or partial failure to observe these warnings.
Should the power cable be found to be damaged, immediately disconnect
from the power socket.
The power supply cables are to be replaced by skilled person-
nel.
4.4 Starting up of the unit
The distributor is equipped with a safety switch (Fig.4.9) that di-
sconnects the machine whenever the door is opened ( see electric
schema).
In case of necessity, therefore, open the door or disconnect unplugging of
the machine from the power supply.
The clamp of the power cable junction box remain under ten-
sion (Fig.4.10-pos.1) as well as the service switch inside the
distributor. (Fig.4.11-pos.2).
– For some operations is however necessary operate with the door open
but with the distributor connected.
It is possible for installation technician, to operate in this way, by inserting
the special plastic key, supplied with the distributor, into the door switch
and rotating it 90° (Fig.4.12).
The opening and the possible connection with the distributor's door
open must be performed only by authorized in carrying out these
operations.
Don't leave the distributor open and unguarded.
Give the key only to qualified personnel.
Any time the distributor is switched on there is a diagnosis cycle to check the
state of DA peripherals and perform the restoration of moving parts.
14
with a power supply cable of H05VV-F

Publicidad

loading

Este manual también es adecuado para:

Bvm 972